14 TROUBLESHOOTING
14.5 List of Error Codes
593
14
1926H
Start not possible
Start is requested when "[Cd.100] Servo OFF
command" is "1: Servo OFF".
[Operation status at error occurrence]
The system does not start positioning.
Set "0: Servo ON" in the "[Cd.100] Servo OFF
command".
1927H
Start not possible
Start is requested when the servo alarm occurs.
[Operation status at error occurrence]
The system does not start positioning.
Reset the error after removing the servo alarm
referring to the "Servo Amplifier Instruction Manual".
1928H
Start not possible
Start is requested during the forced stop of controller.
[Operation status at error occurrence]
The system does not start positioning.
Remove the cause of forced stop.
1929H
Start not possible
Start is requested when the servo READY signal is
turned OFF.
[Operation status at error occurrence]
The system does not start positioning.
Do not request the start when the servo READY signal
is turned OFF.
1930H
Hold error
In the CPU module parameter "Output at error stop",
the setting for the Simple Motion module is "Hold".
[Operation status at error occurrence]
At start: The system does not operate.
During operation: The system stops with the setting
(deceleration stop/sudden stop) of the detailed
parameter 2 sudden stop selection (stop group 3). (Note
that the deceleration stop only occurs during the
manual pulse generator operation.)
Clear the setting of the CPU module parameter
"Output at error stop".
1931H
Flash ROM write
error
Data is not written to the flash ROM.
[Operation status at error occurrence]
At start: The system does not operate.
The flash ROM is expected to be at the end of its
writable life.
1932H
Flash ROM sum
check error
While data is written to the flash ROM, the power is
turned OFF.
[Operation status at error occurrence]
At start: The system does not operate.
Reset the parameter and write it to a Flash ROM
again.
1933H
Flash ROM sum
check error
While data is written to the flash ROM in the
synchronous parameter area, the power is turned OFF.
[Operation status at error occurrence]
At start: The system does not operate.
Reset the parameter and write to the flash ROM again.
1934H
Synchronous
restoration data sum
check error
Synchronous restoration data reading is failure.
[Operation status at error occurrence]
The synchronous control initial value cannot be
restored.
The internal memory (nonvolatile) is expected to be at
the end of its writable life. Exchange the module.
193EH
Connected device
setting error
The setting value (vendor ID, identification code) of the
"[Pr.100] Connected device" and the actually connected
device is mismatch.
[Operation status at error occurrence]
The communication between the connected devices or
later of target axis is not executed.
Match the setting value of the "[Pr.100] Connected
device" to the actually connected device.
193FH
Operation cycle time
over error
The calculation process time of the positioning etc.
exceeds the operation cycle.
[Operation status at error occurrence]
The operation continues.
Review the content of the positioning or "[Pr.96]
Operation cycle setting" longer than the current setting.
1940H
Start at home
position
• When the home position return retry invalid is set, the
near-point dog method machine home position return
is started with the home position return complete flag
turned ON.
• Scale origin signal detection method machine home
position return is started with the home position return
complete flag turned ON and the near-point dog
signal turned ON.
[Operation status at error occurrence]
The machine home position return does not start.
• Validate the home position return retry function (set
value: 1).
• Move the work piece from the current position (on
home position) using the manual control operation,
then carry out a machine home position return again.
Error code
(Hexadecimal)
Error name
Error details and causes
Remedy
Содержание RD77MS16
Страница 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...
Страница 2: ......
Страница 316: ...314 9 COMMON FUNCTIONS 9 4 External Input Signal Select Function Program example ...
Страница 317: ...9 COMMON FUNCTIONS 9 4 External Input Signal Select Function 315 9 ...
Страница 574: ...572 13 PROGRAMMING 13 4 Positioning Program Examples Parameter initialization program Flash ROM write program ...
Страница 575: ...13 PROGRAMMING 13 4 Positioning Program Examples 573 13 Error reset program Axis stop program ...
Страница 643: ......