8 CONTROL SUB FUNCTIONS
8.8 Functions Related to Stop
273
8
Step function
The "step function" is used to confirm each operation of the positioning control one by one.
It is used in debugging work for major positioning control, etc.
A positioning operation in which a "step function" is used is called a "step operation".
In step operations, the timing for stopping the control can be set. (This is called the "step mode".) Control stopped by a step
operation can be continued by setting "step continues (to continue the control)" in the "step start information".
Relation between the step function and various controls
The following table shows the relation between the "step function" and various controls.
: Set when required,
: Setting not possible
Step mode
In step operations, the timing for stopping the control can be set. This is called the "step mode". (The "step mode" is set in the
control data "[Cd.34] Step mode".)
The following shows the two types of "step mode" functions.
■
Deceleration unit step
The operation stops at positioning data requiring automatic deceleration. (A normal operation will be carried out until the
positioning data requiring automatic deceleration is found. Once found, that positioning data will be executed, and the
operation will then automatically decelerate and stop.)
■
Data No. unit step
The operation automatically decelerates and stops for each positioning data. (Even in continuous path control, an automatic
deceleration and stop will be forcibly carried out.)
Control type
Step function
Step applicability
Home position return
control
Machine home position return control
Step operation not possible
Fast home position return control
Major positioning control
Position control
1-axis linear control
Step operation possible
2 to 4-axis linear interpolation control
1-axis fixed-feed control
2 to 4-axis fixed-feed control (interpolation)
2-axis circular interpolation control
3-axis helical interpolation control
1 to 4-axis speed control
Step operation not possible
Speed-position switching control, Position-speed switching control
Step operation possible
Other control
Current value changing
JUMP instruction, NOP instruction, LOOP to LEND
Step operation not possible
Manual control
JOG operation, Inching operation
Step operation not possible
Manual pulse generator operation
Expansion control
Speed-torque control
Содержание RD77MS16
Страница 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...
Страница 2: ......
Страница 316: ...314 9 COMMON FUNCTIONS 9 4 External Input Signal Select Function Program example ...
Страница 317: ...9 COMMON FUNCTIONS 9 4 External Input Signal Select Function 315 9 ...
Страница 574: ...572 13 PROGRAMMING 13 4 Positioning Program Examples Parameter initialization program Flash ROM write program ...
Страница 575: ...13 PROGRAMMING 13 4 Positioning Program Examples 573 13 Error reset program Axis stop program ...
Страница 643: ......