5 MANUAL CONTROL
5.2 JOG Operation
169
5
Setting the required parameters for JOG operation
The "Positioning parameters" must be set to carry out JOG operation.
The following table shows the setting items of the required parameters for carrying out JOG operation. Parameters not shown
below are not required to be set for carrying out only JOG operation. (Set the initial value or a value within the setting range.)
: Setting always required.
: Set according to requirements (Set the initial value or a value within the setting range when not used.)
Refer to the following for the setting details.
• Parameter settings work in common for all controls using the Simple Motion module. When carrying out
other controls ("major positioning control", "high-level positioning control", "home position return positioning
control"), set the respective setting items as well.
• Parameters are set for each axis.
Setting item
Setting requirement
Positioning
parameters
[Pr.1]
Unit setting
[Pr.2]
Number of pulses per rotation (AP) (Unit: pulse)
[Pr.3]
Movement amount per rotation (AL) (Unit: pulse)
[Pr.4]
Unit magnification (AM)
[Pr.7]
Bias speed at start (Unit: pulse/s)
[Pr.8]
Speed limit value (Unit: pulse/s)
[Pr.9]
Acceleration time 0 (Unit: ms)
[Pr.10]
Deceleration time 0 (Unit: ms)
[Pr.11]
Backlash compensation amount (Unit: pulse)
[Pr.12]
Software stroke limit upper limit value (Unit: pulse)
[Pr.13]
Software stroke limit lower limit value (Unit: pulse)
[Pr.14]
Software stroke limit selection
[Pr.15]
Software stroke limit valid/invalid setting
[Pr.17]
Torque limit setting value (Unit: 0.1%)
[Pr.25]
Acceleration time 1 (Unit: ms)
[Pr.26]
Acceleration time 2 (Unit: ms)
[Pr.27]
Acceleration time 3 (Unit: ms)
[Pr.28]
Deceleration time 1 (Unit: ms)
[Pr.29]
Deceleration time 2 (Unit: ms)
[Pr.30]
Deceleration time 3 (Unit: ms)
[Pr.31]
JOG speed limit value (Unit: pulse/s)
[Pr.32]
JOG operation acceleration time selection
[Pr.33]
JOG operation deceleration time selection
[Pr.34]
Acceleration/deceleration process selection
[Pr.35]
S-curve ratio (Unit: %)
[Pr.36]
Sudden stop deceleration time (Unit: ms)
[Pr.37]
Stop group 1 sudden stop selection
[Pr.38]
Stop group 2 sudden stop selection
[Pr.39]
Stop group 3 sudden stop selection
Содержание RD77MS16
Страница 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...
Страница 2: ......
Страница 316: ...314 9 COMMON FUNCTIONS 9 4 External Input Signal Select Function Program example ...
Страница 317: ...9 COMMON FUNCTIONS 9 4 External Input Signal Select Function 315 9 ...
Страница 574: ...572 13 PROGRAMMING 13 4 Positioning Program Examples Parameter initialization program Flash ROM write program ...
Страница 575: ...13 PROGRAMMING 13 4 Positioning Program Examples 573 13 Error reset program Axis stop program ...
Страница 643: ......