![Mitsubishi Electric RD77MS16 Скачать руководство пользователя страница 205](http://html.mh-extra.com/html/mitsubishi-electric/rd77ms16/rd77ms16_user-manual_1811857205.webp)
7 EXPANSION CONTROL
7.1 Speed-torque Control
203
7
The following chart shows the operation timing for axis 1.
■
RD77MS4 operation example
t
0
1
0
1
0
0
30
0
**
33
30
0
Torque
30.0%
[Cd.138] Control mode switching request
[Cd.139] Control mode setting
[Cd.150] Target torque at continuous
operation to torque control mode
[Md.26] Axis operation status
t
V
1000
Position control mode
Continuous operation
to torque control mode
Position control mode
[Cd.147] Speed limit value at continuous
operation to torque control mode
1000
0
0
ON
BUSY signal [X10]
0
0
1
1
0
[Md.124] Control mode switching status
[0, 0]
Control mode
([Md.108] Servo status1: b2, b3)
Continuous operation to torque control
([Md.125] Servo status3: b14)
OFF
OFF
ON
**
300
0
0
Contact with
target
**: Depending on the positioning method.
0
0
6 to 11 ms
6 to 11 ms
Содержание RD77MS16
Страница 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...
Страница 2: ......
Страница 316: ...314 9 COMMON FUNCTIONS 9 4 External Input Signal Select Function Program example ...
Страница 317: ...9 COMMON FUNCTIONS 9 4 External Input Signal Select Function 315 9 ...
Страница 574: ...572 13 PROGRAMMING 13 4 Positioning Program Examples Parameter initialization program Flash ROM write program ...
Страница 575: ...13 PROGRAMMING 13 4 Positioning Program Examples 573 13 Error reset program Axis stop program ...
Страница 643: ......