26
1 START AND STOP
1.2 Stop
*1
If an error occurs in a positioning data due to an invalid setting value, when the continuous positioning control uses multiple positioning
data successively, it automatically decelerates at the previous positioning data. It does not stop suddenly even the setting value is
sudden stop in stop group 3. If any of the following error occurs, the operation is performed up to the positioning data immediately before
the positioning data where an error occurred, and then stops immediately.
No command speed (error code: 1A13H, 1A14H)
Outside linear movement amount range (error code: 1A15H, 1A16H)
Large arc error deviation (error code: 1A17H)
Software stroke limit + (error code: 1A18H, 1A19H)
Software stroke limit - (error code: 1A1AH, 1A1BH)
Sub point setting error (error code: 1A27H, 1A28H, 1A29H, 1A2AH, 1A37H)
End point setting error (error code: 1A2BH, 1A2CH)
Center point setting error (error code: 1A2DH, 1A2EH, 1A2FH)
Outside radius range (error code: 1A32H)
Illegal setting of ABS direction in unit of degree (error code: 19A4H, 19A5H)
Stop cause
Stop process
Home position return
control
Major
positioning
control
High-level
positioning
control
Manual control
Machine
home
position
return
control
Fast home
position
return
control
JOG/
Inching
operation
Manual
pulse
generator
operation
Forced stop
"Forced stop input signal" OFF
from an external device
Servo OFF or free run
(The operation stops with dynamic brake)
Servo READY OFF
• Servo amplifier power supply
OFF
• Servo alarm
• Forced stop input to servo
amplifier
Fatal stop
(Stop group 1)
Hardware stroke limit upper/lower
limit error occurrence
Deceleration stop/sudden stop
(Select with "[Pr.37] Stop group 1 sudden stop selection".)
Deceleration
stop
Emergency stop
(Stop group 2)
Error occurs in a CPU module
Delegation stop/sudden stop
(Select with "[Pr.38] Stop group 2 sudden stop selection".)
Deceleration
stop
PLC READY signal OFF
Error in test mode
Relatively safe
stop
(Stop group 3)
Axis error detection (Error other
than stop group 1 or 2)
Deceleration stop/sudden stop
(Select with "[Pr.39] Stop group 3 sudden stop selection".)
Deceleration
stop
"Stop" input from an engineering
tool
Intentional stop
(Stop group 3)
"Axis stop signal" ON from a CPU
module
"Stop signal" of external input
signal ON
Содержание RD77MS16
Страница 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...
Страница 2: ......
Страница 316: ...314 9 COMMON FUNCTIONS 9 4 External Input Signal Select Function Program example ...
Страница 317: ...9 COMMON FUNCTIONS 9 4 External Input Signal Select Function 315 9 ...
Страница 574: ...572 13 PROGRAMMING 13 4 Positioning Program Examples Parameter initialization program Flash ROM write program ...
Страница 575: ...13 PROGRAMMING 13 4 Positioning Program Examples 573 13 Error reset program Axis stop program ...
Страница 643: ......