![Mitsubishi Electric RD77MS16 Скачать руководство пользователя страница 591](http://html.mh-extra.com/html/mitsubishi-electric/rd77ms16/rd77ms16_user-manual_1811857591.webp)
14 TROUBLESHOOTING
14.4 List of Warning Codes
589
14
0C40H
Outside operation
cam No. range
"[Cd.601] Operation cam No." is other than 1 to 256.
[Operation status at warning occurrence]
Cam data writing/reading is not executed.
Set a value within the range of 1 to 256.
0C41H
Read cam not
registered
Cam data of the specified cam No. does not exist on the
cam open area during the cam data reading operation.
[Operation status at warning occurrence]
Cam data writing/reading is not executed.
• Specify the cam No. of an existing cam data.
• When writing the cam data from a programming tool,
turn the PLC ready signal from OFF to ON and open
the cam data on the cam open area.
0C42H
Outside cam data
first position range
• "[Cd.602] Cam data first position" is outside the range
of "1 to Cam resolution" for the stroke ratio data
format cam.
• "[Cd.602] Cam data first position" is outside the range
of "0 to (Coordinate number - 1)" for the coordinate
data format cam.
[Operation status at warning occurrence]
Cam data writing/reading is not executed.
• Set a value within the range of "1 to Cam resolution"
for the stroke ratio data format cam.
• Set a value within the range of "0 to (Coordinate
number - 1)" for the coordinate data format cam.
0C43H
Outside number of
cam data operation
points range
• "[Cd.603] Number of cam data operation points" is
outside the range of 1 to 4096 for the stroke ratio data
format cam.
• "[Cd.603] Number of cam data operation points" is
outside the range of 1 to 2048 for the coordinate data
format cam.
• First position and number of operation points which
exceed the cam resolution or coordinate number are
set during the cam data writing operation.
[Operation status at warning occurrence]
Cam data writing/reading is not executed.
• Set a value within the range of 1 to 4096 for the
stroke ratio data format cam.
• Set a value within the range of 1 to 2048 for the
coordinate data format cam.
• Set "Cam data first po (Number of cam data
operation points - 1)" not to exceed the cam
resolution.
• Set "Cam data first po (Number of cam data
operation points - 1)" not to exceed the number of
coordinates.
0C44H
Outside cam data
format range
"[Cd.604] Cam data format" is other than 1 or 2 during
the cam data writing operation.
[Operation status at warning occurrence]
Cam data writing/reading is not executed.
Set 1 or 2.
0C45H
Outside cam
resolution/coordinate
number range
• "[Cd.605] Cam resolution/coordinate number" is other
than "256/512/1024/2048/4096/8192/16384/ 32768"
for the stroke ratio data format cam during the cam
data writing operation.
• "[Cd.605] Cam resolution/coordinate number" is
outside the range of "2 to 16384" for the coordinate
data format cam during the cam data writing
operation.
[Operation status at warning occurrence]
Cam data writing/reading is not executed.
• Set a value within the range of "256/512/1024/ 2048/
4096/8192/16384/32768" for the stroke ratio data
format cam.
• Set a value within the range of 2 to 16384 for the
coordinate data format cam.
0C46H
Outside cam data
starting position
range
"[Cd.606] Cam data starting point" is outside the range
from "0 to (Cam resolution - 1)" during the cam data
writing operation.
[Operation status at warning occurrence]
Cam data writing/reading is not executed.
Set a value within the range of "0 to (Cam resolution -
1)".
0C47H
Cam storage area
capacity over
• The free area in the cam storage area is insufficient
during the cam data writing operation.
• The writable area is insufficient due to the decoupling
of free area.
[Operation status at warning occurrence]
Cam data writing/reading is not executed.
• Decrease the number of cam data (number of cams,
cam resolution, and coordinate number).
• Erase the cam data and rewrite it.
0C48H
Cam open area
capacity over
• The free area in the cam open area is insufficient
during the cam data writing operation.
• The writable area is insufficient due to the decoupling
of free area.
[Operation status at warning occurrence]
Cam data writing/reading is not executed.
• Decrease the number of cam data (number of cams,
cam resolution, and coordinate number).
• Erase the cam data and rewrite it.
0C49H
Coordinate data
error
• Input value of coordinate data is a negative value
during the cam data writing operation.
• Input value of coordinate data is not "X
n
< X
n+1
"
during the cam data writing operation.
[Operation status at warning occurrence]
Cam data writing/reading is not executed.
• Set the Input value of coordinate data to 0 or more.
• Set the Input value of coordinate data to "X
n
< X
n+1
".
0C4AH
Cam data reading
operation inhibit
Cam data reading operation is executed with the cam
data read password set.
[Operation status at warning occurrence]
Cam data writing/reading is not executed.
Delete the cam data read password with a
programming tool.
Warning code
(Hexadecimal)
Warning name
Error details and causes
Remedy
Содержание RD77MS16
Страница 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...
Страница 2: ......
Страница 316: ...314 9 COMMON FUNCTIONS 9 4 External Input Signal Select Function Program example ...
Страница 317: ...9 COMMON FUNCTIONS 9 4 External Input Signal Select Function 315 9 ...
Страница 574: ...572 13 PROGRAMMING 13 4 Positioning Program Examples Parameter initialization program Flash ROM write program ...
Страница 575: ...13 PROGRAMMING 13 4 Positioning Program Examples 573 13 Error reset program Axis stop program ...
Страница 643: ......