APPENDICES APPENDIX
Appendix 3 Compatible Devices with SSCNETIII(/H)
Inverter FR-A700 series
FR-A700 series can be connected via SSCNET
by using built-in option FR-A7AP and FR-A7NS.
Connecting method
■
System configuration
The system configuration using FR-A700 series is shown below.
Set "0: SSCNET
" in "[Pr.97] SSCNET setting" to use FR-A700 series.
■
Parameter setting
To connect FR-A700 series, execute flash ROM writing after setting the following parameters to buffer memory. The setting
value is valid when the power supply is turned ON or the CPU module is reset.
"[Pr.97] SSCNET setting": "0: SSCNET
"
"[Pr.100] Connected device": "00004100H: FR-A700 (Inverter)", "00004101H: FR-A700-NA (Inverter)", "00004102H: FR-
A700-EC (Inverter)", "00004103H: FR-A700-CHT (Inverter)"
■
Control of FR-A700 series parameters
Parameters set in FR-A700 series are not controlled by Simple Motion module. Set the parameters by connecting FR-A700
series directly with the operation panel on the front of inverter (FR-DU07/FR-PU07) or FR Configurator that is inverter setup
software. Confirm the specifications of FR-A700 series for details of the setting items.
In the state of connecting between FR-A700 series and Simple Motion module, only a part of parameters can
be set if the parameter of the inverter "[Pr.77] Parameter write selection" is in the initial state. Set "2: Write
parameters during operation" to rewrite the parameters of FR-A700 series.
SSCNET
µ
SSCNET
µ
cable
MR-J3BUS_M(-A/-B)
RD77MS2 : Up to 2 axes
RD77MS4 : Up to 4 axes
RD77MS8 : Up to 8 axes
RD77MS16 : Up to 16 axes
Servo amplifier
MR-J3(W)-_B
Inverter
FR-A700 series
Simple Motion module
RD77MS4
ERR
RUN
AX
3
4
2
1
AX
Содержание RD77MS16
Страница 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...
Страница 2: ......
Страница 316: ...314 9 COMMON FUNCTIONS 9 4 External Input Signal Select Function Program example ...
Страница 317: ...9 COMMON FUNCTIONS 9 4 External Input Signal Select Function 315 9 ...
Страница 574: ...572 13 PROGRAMMING 13 4 Positioning Program Examples Parameter initialization program Flash ROM write program ...
Страница 575: ...13 PROGRAMMING 13 4 Positioning Program Examples 573 13 Error reset program Axis stop program ...
Страница 643: ......