3 MAJOR POSITIONING CONTROL
3.2 Setting the Positioning Data
■
Setting method for the current value changing function
The following shows an example of a program and data setting to change the current value to a new value with the positioning
start signal. (The "[Md.20] Current feed value" value is changed to "5000.0
m" in the example shown.)
• Set the following data. (Set using the program referring to the start time chart.)
n: Axis No. - 1
*1
Refer to the following for details on the setting details.
• The following shows a start time chart.
■
RD77MS4 operation example
Setting item
Setting value
Setting details
Buffer memory address
[Cd.3]
Positioning start No.
9003
Set the start No. "9003" for the new current value.
4300+100n
[Cd.9]
New current value
50000
Set the new "[Md.20] Current feed value".
4306+100n
4307+100n
Positioning start signal
[Y10]
PLC READY signal
[Y0]
READY signal
[X0]
Start complete signal
([Md.31] Status: b14)
BUSY signal
[X10]
Positioning complete signal
([Md.31] Status: b15)
[Cd.3] Positioning start No.
9003
V
t
Error detection signal
([Md.31] Status: b13)
[Md.20] Current feed value
50000
[Cd.9] New current value
Start of data No. 9003
Data No. during
positioning execution
Address during
positioning execution
50000
Содержание RD77MS16
Страница 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...
Страница 2: ......
Страница 316: ...314 9 COMMON FUNCTIONS 9 4 External Input Signal Select Function Program example ...
Страница 317: ...9 COMMON FUNCTIONS 9 4 External Input Signal Select Function 315 9 ...
Страница 574: ...572 13 PROGRAMMING 13 4 Positioning Program Examples Parameter initialization program Flash ROM write program ...
Страница 575: ...13 PROGRAMMING 13 4 Positioning Program Examples 573 13 Error reset program Axis stop program ...
Страница 643: ......