![Mitsubishi Electric RD77MS16 Скачать руководство пользователя страница 249](http://html.mh-extra.com/html/mitsubishi-electric/rd77ms16/rd77ms16_user-manual_1811857249.webp)
8 CONTROL SUB FUNCTIONS
8.4 Functions to Limit the Control
247
8
Wiring the forced stop
When using the forced stop function, wire the terminals of the Simple Motion module forced stop input as shown in the
following drawing. As for the 24 V DC power supply, the direction of current can be switched.
Setting the forced stop
To use the "Forced stop function", set the following data using a program.
The set details are validated at the rising edge (OFF
ON) of the PLC READY signal [Y0].
Refer to the following for the setting details.
How to check the forced stop
To use the states (ON/OFF) of forced stop input, set the parameters shown in the following table.
Refer to the following for the setting details.
Precautions during control
• After the "Forced stop input" is released, the servo ON/OFF is valid for the status of all axis servo ON [Y1].
• If the setting is other than 0 and 1, the error "Forced stop valid/invalid setting error" (error code: 1B71H) occurs.
• The "[Md.50] Forced stop input" is stored "1" by setting "[Pr.82] Forced stop valid/invalid selection" to "1: invalid".
• When the "Forced stop input" is turned ON during operation, the error "Servo READY signal OFF during operation" (error
code: 1902H) does not occur.
Setting item
Setting
value
Setting details
Buffer memory address
[Pr.82]
Forced stop valid/ invalid selection
Set the forced stop function.
35
0: Valid
Forced stop is used
1: Invalid
Forced stop is not used
Monitor item
Monitor
value
Storage details
Buffer memory
address
[Md.50]
Forced stop input
Stores the states (ON/OFF) of forced stop input.
0: Forced stop input ON (Forced stop)
1: Forced stop input OFF (Forced stop release)
4231
Simple Motion module
EMI
EMI.COM
24 V DC
Содержание RD77MS16
Страница 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...
Страница 2: ......
Страница 316: ...314 9 COMMON FUNCTIONS 9 4 External Input Signal Select Function Program example ...
Страница 317: ...9 COMMON FUNCTIONS 9 4 External Input Signal Select Function 315 9 ...
Страница 574: ...572 13 PROGRAMMING 13 4 Positioning Program Examples Parameter initialization program Flash ROM write program ...
Страница 575: ...13 PROGRAMMING 13 4 Positioning Program Examples 573 13 Error reset program Axis stop program ...
Страница 643: ......