14 TROUBLESHOOTING
14.5 List of Error Codes
603
14
1A29H
Sub point setting
error
Start point, end point, and sub point are in line with each
other in the circular interpolation with sub points
designated.
[Operation status at error occurrence]
At start: The system does not operate.
During operation: The system stops immediately.
Correct the sub address (arc address).
1A2AH
Sub point setting
error
Sub point address is outside the range of -2147483648
to 2147483647 in the circular interpolation with sub
points designated.
[Operation status at error occurrence]
At start: The system does not operate.
During operation: The system stops immediately.
Correct the sub address (arc address).
1A2BH
End point setting
error
Start point is equal to end point in the circular
interpolation with sub points designated.
[Operation status at error occurrence]
At start: The system does not operate.
During operation: The system stops immediately.
Correct the end address (positioning address).
1A2CH
End point setting
error
End point address is outside the range of -2147483648
to 2147483647 in the circular interpolation with auxiliary
point designation and center point designation.
[Operation status at error occurrence]
At start: The system does not operate.
During operation: The system stops immediately.
Correct the end address (positioning address).
1A2DH
Center point setting
error
Start point is equal to center point in the circular
interpolation with center point designation.
[Operation status at error occurrence]
At start: The system does not operate.
During operation: The system stops immediately.
Correct the center point address (arc address).
1A2EH
Center point setting
error
End point is equal to center point in the circular
interpolation with center point designation.
[Operation status at error occurrence]
At start: The system does not operate.
During operation: The system stops immediately.
Correct the center point address (arc address).
1A2FH
Center point setting
error
Center point address is outside the range of
-2147483648 to 2147483647 in the circular
interpolation with center point designation.
[Operation status at error occurrence]
At start: The system does not operate.
During operation: The system stops immediately.
Correct the center point address (arc address).
1A30H
Outside address
range
In the speed-position switching control and the position-
speed switching control, the setting value of a
positioning address is negative.
[Operation status at error occurrence]
At start: The system does not operate.
During operation: The system stops with the setting
(deceleration stop/sudden stop) of the detailed
parameter 2 sudden stop selection (stop group 3). (Note
that the deceleration stop only occurs during the
manual pulse generator operation.)
Correct the positioning address.
1A31H
Outside address
range
In ABS1, ABS2, ABS3 and ABS4, the setting value of a
positioning address is outside the range of 0 to
359.99999 degrees.
[Operation status at error occurrence]
At start: The system does not operate.
During operation: The system stops with the setting
(deceleration stop/sudden stop) of the detailed
parameter 2 sudden stop selection (stop group 3). (Note
that the deceleration stop only occurs during the
manual pulse generator operation.)
Correct the positioning address.
1A32H
Outside radius range
The arc radius exceeds 536870912.
[Operation status at error occurrence]
At start: The system does not operate.
During operation: The system stops immediately.
Correct the positioning data.
1A33H
Control method
LOOP setting error
A "0" is set in the repeating times of the control method
"LOOP".
[Operation status at error occurrence]
The operation is terminated.
Set 1 to 65535 in the repeating time of LOOP.
Error code
(Hexadecimal)
Error name
Error details and causes
Remedy
Содержание RD77MS16
Страница 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...
Страница 2: ......
Страница 316: ...314 9 COMMON FUNCTIONS 9 4 External Input Signal Select Function Program example ...
Страница 317: ...9 COMMON FUNCTIONS 9 4 External Input Signal Select Function 315 9 ...
Страница 574: ...572 13 PROGRAMMING 13 4 Positioning Program Examples Parameter initialization program Flash ROM write program ...
Страница 575: ...13 PROGRAMMING 13 4 Positioning Program Examples 573 13 Error reset program Axis stop program ...
Страница 643: ......