544
12 DATA USED FOR POSITIONING CONTROL
12.9 Memory Configuration and Data Process
Buffer memory area configuration
The buffer memory of Simple Motion module is configured of the following types of areas.
n: Axis No. - 1
k: Mark detection setting No. - 1
j: Synchronous encoder axis No. - 1
Buffer memory area configuration
Buffer memory address
Writing
possibility
Parameter area
Servo network composition parameter area
58020 to 58659
Possible
Common parameter area
33, 35, 67, 105, 106, 58000 to 58008
Basic parameter area
0+150n to 15+150n
Detailed parameter area
17+150n to 69+150n
Home position return basic parameter area
70+150n to 78+150n
Home position return detailed parameter area
79+150n to 91+150n
Expansion parameter area
100+150n to 149+150n
Mark detection setting parameter area
54000+20k to 54019+20k
Monitor data area
System monitor area
4000 to 4299
31300 to 31549
Not possible
Axis monitor area
2400+100n to 2499+100n
Servo network composition monitor area
58660 to 59328
Mark detection monitor data area
54960+80k to 55039+80k
Control data area
System control data area
5900 to 5999
Possible
Axis control data area
4300+100n to 4399+100n
30100+10n to 30109+10n
Mark detection control data area
54640+10k to 54649+10k
Positioning data area (No.1 to 100)
Positioning data area
6000+1000n to 6999+1000n
71000+1000n, 71001+1000n
Possible
Positioning data area (No.101 to 600)
Set with the engineering tool.
Block start data area
(No.7000)
Block start data area
22000+400n to 22049+400n
22050+400n to 22099+400n
Condition data area
22100+400n to 22199+400n
Block start data area
(No.7001)
Block start data area
22200+400n to 22249+400n
22250+400n to 22299+400n
Condition data area
22300+400n to 22399+400n
Block start data area
(No.7002)
Block start data area
Set with the engineering tool.
Condition data area
Block start data area
(No.7003)
Block start data area
Condition data area
Block start data area
(No.7004)
Block start data area
Condition data area
PLC CPU memo area
PLC CPU memo area
30000 to 30099
Possible
Servo parameter area
PA group
PA01 to PA18
28401+100n to 28418+100n
Possible
PA19
64464+70n
PA20 to PA32
64400+70n to 64412+70n
PB group
28419+100n to 28463+100n
64413+70n to 64431+70n
PC group
28464+100n to 28495+100n
64432+70n to 64463+70n
PD group
65520+340n to 65567+340n
PE group
65568+340n to 65631+340n
PS group
65712+340n to 65743+340n
PF group
65632+340n to 65679+340n
Po group
65680+340n to 65711+340n
PL group
65744+340n to 65791+340n
Содержание RD77MS16
Страница 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...
Страница 2: ......
Страница 316: ...314 9 COMMON FUNCTIONS 9 4 External Input Signal Select Function Program example ...
Страница 317: ...9 COMMON FUNCTIONS 9 4 External Input Signal Select Function 315 9 ...
Страница 574: ...572 13 PROGRAMMING 13 4 Positioning Program Examples Parameter initialization program Flash ROM write program ...
Страница 575: ...13 PROGRAMMING 13 4 Positioning Program Examples 573 13 Error reset program Axis stop program ...
Страница 643: ......