3 - 8
3. CC-LINK COMMUNICATION FUNCTIONS
3.4 Servo amplifier setting
(1) Servo amplifier side operation modes
This servo amplifier has the following operation modes:
Operation mode
Description
Test operation mode
Parameter unit or personal computer in which MR Configurator is installed is used to run the
servo motor.
CC-Link operation mode
CC-Link communication functions are used to operate the servo with the PLC programs.
(2) Operation mode changing
(a) Operation mode changing conditions
Change the operation mode after making sure that:
1) The servo motor is at a stop.
2) The forward rotation start (RYn1) or reverse rotation start (RYn2) is OFF.
(b) Operation mode changing method
When changing from test operation to CC-Link operation, deselect test operation by switching power
OFF/ON.
Test operation mode is selected using a parameter unit
or a personal computer in which MR Configurator is
installed.
Deselect test operation mode by switching power
OFF/ON.
CC-Link
operation mode
Test operation mode