6 - 28
6. PARAMETERS
6.4 I/O setting parameters (No. PD )
6.4.1 Parameter list
No. Symbol
Name
Initial
Value
Unit
PD01 *DIA1 Input signal automatic ON selection 1
0000h
PD02
For manufacturer setting
0000h
PD03 *DIA3 Input signal automatic ON selection 3
0000h
PD04 *DIA4 Input signal automatic ON selection 4
0000h
PD05
For manufacturer setting
0000h
PD06
*DI2
Input signal device selection 2 (CN6-2)
002Bh
PD07
*DI3
Input signal device selection 3 (CN6-3)
000Ah
PD08
*DI4
Input signal device selection 4 (CN6-4)
000Bh
PD09 *DO1 Input signal device selection 1 (CN6-pin 14)
0002h
PD10 *DO2 Input signal device selection 2 (CN6-pin 15)
0003h
PD11 *DO3 Input signal device selection 3 (CN6-pin 16)
0024h
PD12 DIN1 External DI function selection 1
0C00h
PD13
For manufacturer setting
0000h
PD14 DIN3 External DI function selection 3
0800h
PD15
For manufacturer setting
0000h
PD16 *DIAB Input
polarity
selection
0000h
PD17
0000h
PD18
For manufacturer setting
0000h
PD19 *DIF Response
level
setting
0002h
PD20 *DOP1 Function selection D-1
0010h
PD21
For manufacturer setting
0000h
PD22 *DOP3 Function selection D-2
0000h
PD23
For manufacturer setting
0000h
PD24 *DOP5 Function selection D-5
0000h
PD25
0000h
PD26
0000h
PD27
0000h
PD28
0000h
PD29
0000h
PD30
For manufacturer setting
0000h