5 - 9
5. STARTUP
(2) Indication list
Indication Status
Description
b # # Waiting for CC-Link
communication
Power of the CC-Link master module was switched on at the condition that the power of
CC-Link master module is OFF.
The CC-Link master module is faulty.
(Note 1) d # # Ready
The servo was switched on after completion of initialization and the servo amplifier is ready
to operate. (This is indicated for 2 seconds.)
(Note 1) C # # Not ready
The servo amplifier is being initialized or an alarm has occurred.
(Note 2) A
Alarm Warning
The alarm No./warning No. that occurred is displayed. (Refer to section 11.4.)
8 8
8
CPU error
CPU watchdog error has occurred.
(Note 3)
0 0.
b
JOG operation positioning operation programmed operation DO forced output single-
step feed
# #.
d
(Note 1)
# #.
C
(Note 4)
Test operation mode
Motor-less operation
Note 1. ## denotes any of numerals 00 to 16 and what it means is listed below:
## Description
00
Set to the test operation mode.
01
Station number 1
02
Station number 2
03
Station number 3
:
:
:
:
62
Station number 62
63
Station number 63
64
Station number 64
Note 2.
indicates the warning/alarm No.
Note 3. Requires MR Configurator or MR-PRU03 parameter module.