5 - 43
5. STARTUP
(2) Timing chart
0
6ms or more
Creep speed
Moving distance after proximity dog
Home position shift distance
Home position return speed
Automatic/manual selection
(RYn6)
Movement finish (RXnC)
Rough match (RXn2)
Home position return
completion (ZP)
Servo motor speed
Proximity dog (DOG)
Forward rotation start (RYn1)
Reverse rotation start (RYn2)
3ms or less
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Selected point table No.
ON
OFF
ON
OFF
Home position address
Parameter No. PC07
Proximity dog (DOG)
Forward
rotation
0r/min
The parameter No.PC07 (home position return position data) setting value is the positioning address after
the home position return is completed.