13 - 4
13 CHARACTERISTICS
(Note 2)
Servo amplifier-generated heat[W]
Area required for
heat dissipation
Servo amplifier
Servo motor
(Note 1)
Power supply
capacity[kVA]
At rated torque
With servo off
[m
2
]
HF-SP702 10.0
300 25 6.0
HA-LP702 10.6
300 25 6.0
HA-LP601 10.0
260 25 5.2
MR-J3-700T
HA-LP701M 11.0 300 25 6.0
HA-LP11K2
16.0
530
45
11.0
HA-LP801
12.0
390
45
7.8
HA-LP12K1 18.0 580 45 11.6
MR-J3-11KT
HA-LP11K1M 16.0 530 45 11.0
HA-LP15K2 22.0 640 45 13.0
HA-LP15K1 22.0 640 45 13.0
MR-J3-15KT
HA-LP15K1M 22.0 640 45 13.0
HA-LP22K2
33.0
850
55
17.0
HA-LP20K1 30.1 775 55 15.5
HA-LP25K1 37.6 970 55 19.4
MR-J3-22KT
HA-LP22K1M 33.0 850 55 17.0
Note 1. Note that the power supply capacity will vary according to the power supply impedance. This value assumes that the power
factor improving reactor is not used.
2. Heat generated during regeneration is not included in the servo amplifier-generated heat. To calculate heat generated by the
regenerative option, in section 14.2.
Содержание MELSERVO MR-J3-xT
Страница 22: ...8 MEMO ...
Страница 156: ...4 46 4 SIGNALS AND WIRING MEMO ...
Страница 276: ...7 26 7 MR Configurator MEMO ...
Страница 324: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Страница 418: ...14 66 14 OPTIONS AND AUXILIARY EQUIPMENT MEMO ...