5 - 16
5. STARTUP
(3) Automatic operation timing chart
The timing chart is shown below.
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
0r/min
ON
OFF
ON
OFF
2
1
ON
OFF
1
2
Automatic/manual
selection (RYn6)
Servo-on (RYn0)
Forward rotation
start (RYn1)
Reverse rotation
start (RYn2) (Note 1)
Point table No.
Servo motor speed
Forward
rotation
Reverse
rotation
In position (RXn1)
Rough match (RXn2)
Movement finish
(RXnC)
Point table No. output
(RX(n+2)2 to RX(n+2)9)
Ready (RXn0)
Trouble (ALM)
6ms or more
3ms or less
Point table No. 2
4ms or more
Note 1. Reverse rotation start (RYn2) is invalid in the absolute value command system.
2. External input signal detection delays by the input filter setting time of parameter No. PD19. Also, make up a sequence
that will change the point table selection earlier by the time that takes into account the output signal sequence from
the controller and the variation of a signal change due to the hardware.
6ms or more
(Note 2)
4ms or more
Point table No. 1