5 - 33
5. STARTUP
(3) Timing chart
ON
OFF
ON
OFF
ON
OFF
td
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
0
Selected point table No.
Movement finish (RXnC)
Rough match (RXn2)
Home position return
completion (ZP)
Servo motor speed
Z-phase
Proximity dog (DOG)
Forward rotation start
(RYn1)
Home position
6ms or more
Point table No. 1
Acceleration time
constant
Home position return
speed Parameter No. PC04
Point table No. 1
Deceleration time constant
Creep speed
Parameter No. PC05
Home position shift
distance Parameter No. PC06
Home position address
Parameter No. PC07
3ms or less
Reverse rotation start
(RYn2)
0r/min
Automatic/manual selection
(RYn0)
Forward
rotation
Proximity dog
The parameter No.PC07 (home position return position data) setting value is the positioning address after
the home position return is completed.
(4) Adjustment
In dog type home position return, adjust to ensure that the Z-phase signal is generated during dog
detection. Locate the rear end of the proximity dog (DOG) at approximately the center of two consecutive Z-
phase signals.
The position where the Z-phase signal is generated can be monitored in "Within one-revolution position" of
"Status display" of the MR Configurator or the parameter unit.
OF
0
131072
0
ON
Servo motor Z
phase
Proximity dog
(DOG)
Proximity
dog