14. OPTIONS AND AUXILIARY EQUIPMENT
14.6 External dynamic brake
POINT
Configure up a sequence which switches off the contact of the brake unit after
(or as soon as) it has turned off the servo on signal at a power failure or
failure.
For the braking time taken when the dynamic brake is operated, refer to
section 13.3.
The brake unit is rated for a short duration. Do not use it for high duty.
When the dynamic brake is used, the power supply voltage is restricted as
indicated below.
3-Phase 170 to 220VAC/50Hz
3-Phase 170 to 242VAC/60Hz