Hardware
Error Message
on Display
Possible
Cause
Corrective Action
The PC behind
the IP Phone is
changing speed
100/10.
Depending on the NIC, you may need to
hardcode to 100 MBps instead of auto
negotiation.
IP phone fails to
receive Keepalive
message in 30
seconds.
Verify if the network or the controller is down.
Waiting for link
OR
Lost link to Server
There is electrical
interference.
Verify the power source, and change the
location of the power source.
Unable to register
IP phones due
to regproc trap.
Other symptoms
once a regproc
trap has occurred
are as follows:
•
Can't reregister
a phone that
was already
registered.
•
Can't log in hot
desk users.
•
Phone stays up
after deleting a
MAC.
IP Phone has
tried to register
more than
10 times in
succession
without success.
Refer to Mitel Knowledge Base article
06-9999-00024.