Hardware
Alarm
Probable Cause
Corrective Action
Two PSU
Power supply unit is
defective (AX/MXe III).
Replace the PSU (see Note below).
RAID Hard Disk
Hard disk has a fault
(MXe III).
If the alarm occurs on the primary
drive, replace the hard disk (see Note
below). Refer to Mitel Knowledge
Base article HO1715. If the alarm
occurs on the secondary drive, check
the primary drive for faults. (In some
cases, the primary drive has a sector
error while the secondary drive is fault
free.)
TDM Clock
Stratum 3 clock
module in controller
has failed.
Replace Stratum 3 clock module.
Temperature
Temperature in the
system is getting too
high.
System has overheated. Cool down
system to clear alarm.
SFT Zones
System Fail Transfer
zones have switched
into SFT mode.
Determine cause for switch to SFT
mode.
SYSID Mismatch
The System
Identification module
or i-button is not
installed or is
incorrect.
Install or replace System Identification
module or i-button.
Document Version 1.0
Troubleshooting Guide
44