background image

 sensazone

installation guide

sensazone

 is an intelligent PIR sensor operated system which controls 

the water supply and the light and fan functions in washrooms. 

The system features can be used in the following scenarios

Scenario

Required control

Required products

1

To control the water supply to one zone, room or area 
of a washroom (with a single/common entrance).

sensazone

 core product

2

To control the water supply and lights and fans to 
one zone, room or area of a washroom (with a single/
common entrance).

sensazone

 core product

sensazone

 Interface Module

sensazone

 Light and Fan Control

3

To control the water supply to multiple areas of a 
washroom simultaneously. Examples include, a 
washroom divided into different areas and a washroom 
with two or more entrances.

sensazone

 core product

sensazone

 Interface Module

Additional Sensor Kits
Additional Valve Kits 

(where applicable, to a maximum of 3 valves per system)

4

To control the water supply, lights and fans to multiple 
areas of a washroom (with two or more entrances).

sensazone

 core product 

sensazone

 Interface Module

sensazone

 Light and Fan Control

Additional Sensor Kits
Additional Valve Kits 

(where applicable, to a maximum of 3 valves per system)

1 System requirements

1

 0118 969 1611 | [email protected] | www.cistermiser.co.uk

Summary of Contents for sensazone SZ/ASK

Page 1: ...rface Module A sensazone Light and Fan Control 3 To control the water supply to multiple areas of a washroom simultaneously Examples include a washroom divided into different areas and a washroom with two or more entrances sensazone core product A sensazone Interface Module Additional Sensor Kits Additional Valve Kits where applicable to a maximum of 3 valves per system 4 To control the water supp...

Page 2: ...adaptor 7 2 x universal fixing plug 8 2 x 6 x 1 1 2 screws 9 4 x 4 x 1 2 screws 10 4 x sticky pads 11 Extension cable to mains power adaptor 1 25m 12 Extension cable to solenoid valve 3m 1 sensazone Interface module 2 Sticky Pads x 2 3 Infrared Control Unit ICU 1 1 Solenoid valve either 15mm 22mm 1 or 11 4 Only supplied with 15mm or 22mm 2 2 3 4 5 6 7 8 9 10 11 12 3 2 0118 969 1611 sales cistermis...

Page 3: ...or 22mm 4 5 Additional Sensor Kit supplied parts 1 Sensor assembly consisting of sensor unit and backplate 2 2 x universal fixing plug 3 2 x 6 x 1 1 2 screws 4 4 x sticky pads 5 Extension Y Cable 1 4 2 3 sensazone Light and Fan Control SZ LFC supplied parts 1 sensazone Light Fan Control 2 Screws x 2 3 Fixings x 2 4 Sticky Pads x 4 1 2 4 5 3 0118 969 1611 sales cistermiser co uk www cistermiser co ...

Page 4: ... in the common entrance the water lights and fans will be activated in all areas of the washroom Example layout for single common entrance Scenario 1 and 2 Example layout for multiple entrances Scenario 3 and Scenario 4 When occupancy is detected at one of the entrances the water lights and fans will be activated in all areas of the washroom DOOR MINIMUM 1 METRE MINIMUM 1 METRE 4 0118 969 1611 sal...

Page 5: ... Grey or rainwater supply to washroom Grey or rainwater supply to washroom Max 3 metres cable length from sensor to power supply Max 100 metre cable length between SZ IF B and SZ LFC D Max 1 85 metres cable length CEILING A A C C E E D B Detection Zone 5 metres Detection Zone 5 metres 2 2 metres 2 2 metres 5 0118 969 1611 sales cistermiser co uk www cistermiser co uk Sensor s installation Refer to...

Page 6: ...and SZ LFC D Sensor s installation Refer to page 7 for details SZ IF installation Refer to page 7 for details SZ LFC installation Refer to page 8 for details Valve installation Refer to page 8 for details Mains power adapter Refer to page 9 for details A B D C E Cold water supply to washroom Cold water supply to washroom Isolating Valve not supplied Isolating Valve not supplied Hot water supply to...

Page 7: ...o go out of the same exit ensure that the wire is routed around the sensor as shown in the diagram below 6 Secure sensor unit to base plate and twist clockwise to lock into position SZ IF Installation Position the sensazone Interface Module SZ IF in accordance with the following 1 The cable length from the SZ IF to the furthest valve must NOT exceed 30m 2 The cable length from the SZ IF to the SZ ...

Page 8: ...ot exceed 8A 4 Connect the live feed for the fans to the FAN contactor Ensure load does not exceed 8A 5 Replace lid with screws provided before restoring power WARNING This is a functional switching device and must not be used for safety or maintenance isolation WARNING This device is intended for use with hazardous voltages The installation and maintenance of this device must be carried out by a ...

Page 9: ... co uk www cistermiser co uk 4 Testing and commissioning start up operation When the sensazone is powered up the LED will be a constant amber for up to 15 seconds after which it will flash amber for 5 seconds The water supply ies into the washroom will now be on for the default run on time of 15 minutes The default run on time can be changed to 30 minutes See the ICU guide in section 7 normal oper...

Page 10: ...device please read these installation instructions carefully SZ ASK Control classification Independent Maximum load 3 x 2W 0 33A 6VDC EMC emissions tested at load Rated temperature range 0 40 deg C Action classification Type 1 Y Pollution classification Degree 1 Ingress protection IP55 or IP65 with respect to room when smooth non porous ceiling tile used factory settings Range 2 2m high x 5m diame...

Page 11: ...5 Component dimensions 134mm 101mm 93mm 130mm 125mm 93mm 93mm 124mm 1 valve 11 4 valve 15mm or 22mm valve 76mm 41mm 82mm 31mm 148mm 11 0118 969 1611 sales cistermiser co uk www cistermiser co uk ...

Page 12: ...nutes Option 2 Run on time adjustment 30 minutes Sequence of programme once option has been selected Wait for single green flashing LED Wait for double green flashing LED Once your option has been chosen the LED will be constant green for 5 seconds Cup your hand over the sensor for 2 seconds to select this option The LED will be constant green for 5 seconds Cup your hand over the sensor for 2 seco...

Page 13: ...figuring sensor sensitivity range Enter into configuration mode Point the ICU at the sensazone and press the 1 the sensor blinks green once Decrease or increase the sensor range by pressing the and buttons respectively The sensor blinks green every time or is pressed and blinks red when the minimum or maximum value is reached Press button to verify the sensor sensitivity setting the sensor display...

Page 14: ...ttons respectively The sensor blinks green every time or is pressed and blinks red when the minimum or maximum value is reached Press button to verify the sensor light threshold setting the sensor displays the current setting by flashing green Single flash minimum sensitivity setting Double flash medium sensitivity setting Triple flash maximum sensitivity setting Save setting and exit ICU configur...

Page 15: ... have not been exceeded There is water in one zone but not all zones Ensure water pressure does not exceed the maximum working pressure of the valve water at outlets at all times Sensor LED not lit Check electrical power supply to the sensor and all electrical connections to the valve If electrical power confirmed please contact Cistermiser for further advice Valves not opening or closing when the...

Page 16: ...is faulty please either contact Cistermiser directly on 0118 969 1611 or at warranty cistermiser co uk with a photograph and the serial number to diagnose the cause of the problem The warranty on Cistermiser products can be extended within one year of date of manufacture at no cost to three years from the date of installation by completing the enclosed warranty card or at www cistermiser co uk war...