ZP1-F Series Operation 
Manual 

P/N 501-415603-2-31 • REV 03.10 • ISS 13NOV13 

Summary of Contents for zp1-f Series

Page 1: ...ZP1 F Series Operation Manual P N 501 415603 2 31 REV 03 10 ISS 13NOV13...

Page 2: ...WEEE directive Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union For proper recycling return this product to your local supplier upon the purcha...

Page 3: ...routing delays 2 Control panel overview 3 User interface for two and four zone control panels 3 User interface for eight zone control panels 4 Operator controls and indicators 5 Audible indicators 9...

Page 4: ...any lost profits or business opportunities loss of use business interruption loss of data or any other indirect special incidental or consequential damages under any theory of liability whether based...

Page 5: ...is not available for all operating modes For more information see Sounder and fire routing delays on page 2 Operating modes Supported operating modes are shown in the table below The default operating...

Page 6: ...each operating mode Table 3 Sounder and fire routing delays Operating mode Sounder delay Fire routing delay Extended fire routing delay EN 54 2 Yes Yes Yes EN 54 2 Evacuation Yes No No EN 54 2 Scandi...

Page 7: ...working Fault LED 8 Reserved for special use 2 9 Expansion I O Fault Disabled LED 10 General Disable button and LED 11 General Test button and LED 12 Configuration controls 13 Reset button and LED 14...

Page 8: ...ystem Fault LED 17 Out of Service LED 18 Earth Fault LED 19 Supply Fault LED 20 Fire Routing Delay button and LED 1 2 21 Fire Routing ON ACK and Fault Disable Test button and LEDs 1 2 Notes 1 Two zone...

Page 9: ...ual call point A yellow LED indicates a fault test or disablement in the corresponding zone A flashing yellow LED indicates a fault A steady yellow LED indicates that the zone is disabled or is being...

Page 10: ...he control panel is connected to a fire network with no faults A steady LED for 30 seconds indicates the control panel is showing local information A continuous steady LED indicates the control panel...

Page 11: ...acknowledges all current events A steady LED indicates that all current events were acknowledged 15 Sounder Start Stop button and LED Red The LED indicates what happens when the button is pressed If t...

Page 12: ...Warning Sounder Delay for NBN S 21 100 Yellow Enables or disables a previously configured fire routing or warning sounders delay For warning sounders this cancels a delay as it counts down and activa...

Page 13: ...teady if a fire routing or warning delay was enabled Control panel buzzer Off Fire alarm Fire alarm status is indicated as follows General Fire Alarm LEDs Flashing if the alarm was activated by a dete...

Page 14: ...n status the panel activates the sounders without detection of a zone alarm The status is indicated as shown below For EN 54 2 evacuation and NBN S 21 100 operation General Fire Alarm LEDs On steady S...

Page 15: ...ion for NBN S 21 100 are indicated as follows General Disable LED On steady Sounder LED On steady yellow Control panel buzzer Off Disabled fire routing or warning for NBN S 21 100 is indicated as foll...

Page 16: ...rvice The control panel is out of service when there is insufficient or no mains or battery power Zone and input detection does not operate but the rest of the system is operational In this state the...

Page 17: ...word using the numeric keypad and then press Enter A long beep and a steady Reset LED indicate that the correct password was entered and that the operator user level is active Three short beeps accomp...

Page 18: ...when the configured delay elapses or when the delay is cancelled A fire alarm activated by a manual call point overrides any configured delay and activates sounders immediately Cancelling an active fi...

Page 19: ...shown for 30 seconds After this time the Networking Fault LED turns off and the control panel shows global local and remote information according to its configuration Example 1 If you have a 16 zone...

Page 20: ...disable a configured fire routing delay or warning delay for NBN S 21 100 Enable or disable a configured extended fire routing delay Test a zone Disable or enable a zone Test sounders or evacuation f...

Page 21: ...till be cancelled while the delay is running and sounders activated by pressing the Sounders Delay button Starting sounders in evacuation mode If the control panel has been configured in EN 54 2 evacu...

Page 22: ...tended fire routing delay switch is activated while the standard fire routing delay elapses This delay option is also available for EN 54 2 and NEN 2535 operating modes if configured during installati...

Page 23: ...est button or Evacuation Fault Disable Test button for NBN S 21 100 Sounders or evacuation for NBN S 21 100 can only be tested when the control panel is in standby state The test is indicated as follo...

Page 24: ...NBN S 21 100 On steady yellow Fire Routing On Ack LED Flashing red Sounders Test signal 3 seconds on 5 seconds off To end the test press the General Test button and then press the Fire Routing On Ack...

Page 25: ...3 buttons to select the option to be disabled the corresponding LED flashes and then press Enter to confirm the disablement Disablement is indicated as follows General Disable LED On steady Correspon...

Page 26: ...ault and alarm events The control panel power supply and battery voltage should be checked Annual maintenance Contact your installation or maintenance contractor to carry out an annual inspection of t...

Page 27: ...rotection equipment type A 2 7 11 Delays to outputs 7 13 Alarm counter 3 8 4 Total loss of the power supply 8 9 Output to fault warning routing equipment 2 10 Test condition 1 Excluding two zone model...

Page 28: ...tion body 0832 Manufacturer UTC CCS Manufacturing Polska Sp Z o o Ul Kolejowa 24 39 100 Ropczyce Poland Authorized EU manufacturing representative UTC Fire Security B V Kelvinstraat 7 6003 DH Weert Th...