Trunking
Symptom
Probable Cause
Corrective Action
Incoming calls fail.
Faulty configuration of trunk
Forms.
Verify in the Trunk
Attributes form that there
is an Answer Point setup
for non-DDI trunks for Day
and Night services.
For dial in trunks, the “Dial
In Trunks Incoming Digit
Modification – Absorb” is
not left blank and that the
“Dial In Trunks Incoming
Digit Modification – Insert”
is set appropriately for dial
in trunks.
All calls on a link fail.
Faulty cable connections,
cable, or card.
Check the status of the
link by using the DTSTAT
READ PLID maintenance
command.
Check the cabling and
cable connections. Test
with a back-to-back cable
to prove the card.
Replace faulty cable or
card.
Only some calls on a
link fail.
Configuration errors in
programming
•
ARS programming error
•
Digit conflict
•
Interconnect Restriction
preventing call
•
Far end fault/programming
Correct programming
through System
Administration Tool.
Document Version 1.0
183
Troubleshooting Guide
Содержание MiVoice Business 3300 ICP
Страница 1: ...MiVoice Business Troubleshooting Guide Release 9 4 SP1 Document Version 1 0 June 2022 ...
Страница 10: ...Introduction Document Version 1 0 Troubleshooting Guide 4 ...
Страница 45: ...Figure 4 DNS setting on MSL server manager ...