Hardware
Symptom Probable Cause
Corrective Action
Mon Apr 20 12:19:00 UTC 2020
hwclock -w
3.2
Verify that the commands were successful
by running the following command:
date; hwclock -r
For example:
date; hwclock -r
Mon Apr 20 12:19:20 UTC 2020
Mon Apr 20 12:19:21 2020 0.000000
seconds
3.3
Reboot the system using the following
command:
reboot
If the system now boots properly(or in the case
of a fresh install gets you to the EULA screen
on the serial port), it means that the issue has
been resolved. After you log in to the Server
Manager, go to the Date time panel and verify
the date time settings and the time-zone.We
recommend that you enable the Network Time
Server if you have access to one.
4.
Execute the
dmesg
command and analyze
the output.
If you see "sched: RT throttlingactivated" soon
after "IP-Config: Complete",it means that the
system is experiencing too much network traffic
and is using too many CPU cycles to handle
the network traffic.