TorqueTrak Revolution Installation Guide  

 
 

Tools Required: Digital multimeter, solder and soldering iron, 
 

 

5/8”, 9/16” and 11/16” socket wrenches,  

 

 

1/8”, 5/32” and 1/4” hex wrenches, and wire strippers 

 

 

 

 
 
 
 

Step 2: 

Secure Rotating Collar to Shaft 

-

  Assemble the Collar on the shaft 

near the gage with lead wires 
toward the gage. 

USE CARE WITH CONNECTORS 

-

  Secure the Collar with bolts 

provided after applying antiseize 
compound to the threads. 

-

  Tighten alternate bolts evenly 

until gap between the halves is 
as shown above. 

 

Step 3: 

Mount Master Control Unit 

-

  Mount Master Control Unit 

(MCU) to a mounting bracket so 
that the back edge of the 
Mounting Block is aligned with 
the back surface of the Collar. 

-

  Remove the MCU cover. 

-

  Connect power supply to Power 

Input connector (green) and 
connect to the mating terminal 
inside MCU. 

 

Step 1: 

Install Strain Gage Sensor 

- Glue gage to shaft at least 1 inch  

(2.5 cm) from the Rotating Collar 
per manufacturer’s instructions.  

- Do not attach Revolution lead wires 

to strain gage at this time. 

(shaft) 

 

Step 5: 

Verify System Operation 

-

  Slide the Main Power switch to ON. 

-

  After 10 seconds, verify that Main System  

Status and Star Bridge lights are on solid. 
(If Main System Status light is flashing or 
Star Bridge light is not on, see 
Troubleshooting Guide on back.) 

-

  Connect ammeter to Torque Signal 

Output Terminals (1 & 2) inside MCU. 

-

  Measure Torque Signal current (mA). 

Reading should be approximately 12 mA. 

-

  Slide Remote Shunt switch inside MCU to 

ON. (Main System Status light will flash.) 

-

  Measure Torque Signal current (mA). 

Reading should be approximately 16 mA. 

-

  Slide Remote Shunt switch inside MCU to 

OFF. (Main System Status light on solid.) 

Star Bridge 

Resistor Set 

Strain Gage Sensor 

(jumper wire) 

Step 6: 

Connect Signal and Gage WIres 

-

  Remove star bridge from lead 

wires and discard. 

-

  Solder leads from collar to gage 

as shown. 

-

  Connect permanent signal leads 

to Signal Output connector 
(black) and connect to the 
mating terminal inside MCU. 

(edge view) 

0.100” (2.5 mm) 

no gap between 

connectors 

0.020” (0.5 mm) 

Main System 

Status Indicator 

Light 

Mounting 

Block 

Step 4: 

Install Stationary Power Coil 

-

  Assemble the Power Coil to 

the Mounting Block with 
screws provided. 

-

  Verify that the Power Coil is 

aligned with the Collar before 
proceeding. Adjust the Collar 
or MCU position if necessary. 

CAUTION: For successful operation 
there should be no metal (other than the 
shaft) within 

1

” (

2.5

 cm) of the Power Coil

 