Item
Function No.
Number Return command set value
Near zero comparison operation 72
06
0: Gross weight; 1: Net weight; 2: OFF; 3: |Gross
weight|;
4 : |Net weight|
Full comparison operation
72
07
0: Gross weight; 1: Net weight; 2: OFF; 3: |Gross
weight|;
4 : |Net weight|
Inlow Monitoring Timer
72
10
0000 to 9999 (Unit: 1 s)
Start above Near Zero at inlow
start
72
15
0: Invalid; 1: Efective
Automatic tare weight cancella-
tion at inlow start
72
16
0: Invalid; 1: Efective
Inlow start delay timer
72
17
0000 to 9999 (Unit: 1 s)
Automatic tare weight after in-
low start delay timer
72
18
0: Invalid; 1: Efective
F. (Coarse) low comparison stop
timer
72
20
0000 to 9999 (Unit: 0.01 s)
M. (Middle) low comparison
stop timer
72
21
0000 to 9999 (Unit: 0.01 s)
D. (Fine) low comparison stop
timer
72
22
0000 to 9999 (Unit: 0.01 s)
Automatic overshoot compen-
sation
72
25
0: Invalid; 1: Efective
Automatic overshoot compen-
sation width
72
26
00000 to 99999 (Unit : 1 D)
Judgment condition
72
30
0: Calming time exceeded
1: Calming time exceeded and stable condition
2: Stable or timer is up
Calming time
72
31
0000 to 9999 (Unit: 0.01 s)
Maximum time of post-batching 72
35
000 to 255 (Unit : 1 time)
Judgment condition after post-
batching
72
36
0: Calming time exceeded
1: Calming time exceeded and stable condition
2: Stable or timer is up
Post-batching time
72
37
0000 to 9999 (Unit: 0.01 s)
Calming time after post-
batching
72
38
0000 to 9999 (Unit: 0.01 s)
Inlow inish signal output time 72
40
0000 to 9999 (Unit: 0.01 s)
Inlow inish output OFF
72
41
0: No condition
1: OL or unstable
2: Near zero
Discharge start at inlow inish
72
45
0: Invalid; 1: Efective
18 Options
Weight indicator CSD-903
Minebea Intec
EN-201
Содержание CSD-903