[CADJ]
Zero ine calibration mode
▼ Zero ine calibration
6.4.1.1
Zero ine calibration
[CADJ]
[ZERO]
If executing span calibration only, press the [NET-GROSS] key to proceed to "Span
ine calibration" after [SPAN]is displayed.
[
✶✶✶✶✶
.
✶
] is the current measuring value. It can display up to 1/10 digit.
Example: Without a decimal point 0 ~ 6000 –> 0.0 ~ 6000.0
With a decimal point 0.0 ~ 600.0 –> 0.00 ~ 600.00
Ensure that there is no weight on the load cell and set the display to ZERO.
[TARE WEIGHT]: Increase the measuring value
Increase continuously by holding down the key.
[NET-GROSS]: Decrease the measuring value
Decrease continuously by holding down the key.
[SET]: Interrupts the setting and returns to [CADJ] display.
[F]: Saves the displayed value and proceeds to the next step.
2. Press the[ON-OFF] key with the[SET] key. [CFUNC] is displayed.
3. Press the [NET-GROSS] key.
[CAL]
[CAL] is displayed.
4. Press the[F] key.
[CCAL]
[CCAL] is displayed.
5. Press the [NET-GROSS] key to display[CADJ]and move to zero ine calibration mode.
1. Press the[F] key from the [CADJ] display to display [ZERO].
2. Press the [F] key. The display changes to [
✶✶✶✶✶
.
✶
].
3. After zero ine calibration, press the [F] key.
The display changes to [SPAN].
Weight indicator CSD-903
6 Calibration