Item
Function No.
Number Return command set value
RS-2332C/422/485 communi-
cation speciication
70
42
00000 to 15121
10
0
: Data bit length
0: 7bit; 1: 8 bit
10
1
: Parity
0: No parity; 1: Even parity; 2: Odd parity
10
2
: Stop bit 0: 1bit; 1: 2 bit
10
3
: Baud rate
0: 1,200 bps; 1: 2,400 bps; 2: 4,800 bps;
3: 9,600 bps; 4: 19,200 bps; 5: 38,400 bps
10
4
: Terminator 0: CR; 1: CR+LF
RS-422/485 Address setting
70
43
00 to 31
RS-422/485 changeover
70
44
0: RS-422; 1: RS-485
RS-485 reply data delay time
70
45
00 to 99; Unit: 10 ms)
RS-232C/422/485
transmission data decimal point
usage
70
46
0: None; 1: Present
Standard RS-485 operation
70
47
0: Command mode; 1: Modbus mode
2: Stream mode; 3: Synchronized with inish sig-
nal;
4: Synchronized with accumulation signal;
5: Synchronized with print signal
Standard RS-485 output target 70
48
0: Display interlock; 1: Gross weight; 2: Net
weight;
3: Conditional displayed data
RS-422/RS-485 operation mo-
de
70
49
0: Command mode; 1: Stream mode
Accumulation function opera-
ting condition
70
50
000 to 121
10
0
: Accumulation command operation
0: Only when stable; 1: Always
10
1
: Automatic accumulation operation
0: OFF; 1: Synchronized with inish;
2: Automatic accumulation function
10
2
: Automatic accumulation condition
0: Only in OK mode; 1: No condition
Brand changeover target
70
51
0: Changeover by function
1: Changeover by external control input
2: Changeover by communication
Brand number
70
52
0 to 7
Setting F key operation
70
55
0: OFF; 1: Print Input; 2: Hold Input;
3: Inlow start; 4: Emergency stop; 5: Zero clear;
6: Tare weight clear; 7: Accumulation clear;
8: Weighing comparison;
9: Forced inlow inish
Weight indicator CSD-903