6: Tare weight clear
Executes tare weight cancellation
7: Accumulation clear
Clears the accumulation value and accumulation times
8: Weighing comparison
Switches to check setting mode
9: Forced inlow inish
Force-inishes weighing operation
10.14 External control I/O settings
Set the external control I/O. The I/O connecter is mounted on the rear panel of the device.
10.14.1 External control input setting method
The external control input operation is selected by functions F-60 to F68.
Setting range: 00 to 23
0: OFF
No setting
1: ON/OFF key
The same operation as the ON/OFF key
2: Setting key
The same operation as the setting key
3: Accumulation key
The same operation as the accumulation key
4: Preset tare weight key
The same operation as the preset tare weight key
5: Tare weight key
The same operation as the tare weight key
6: Gross/Net key
The same operation as the gross/net key
7: Zero key
The same operation as the zero key
8: F key
The same operation as the F key
9: Zero clear
After zero set and zero tracking are executed, the display
returns to its former status.
10: Tare weight clear
After tare weight cancellation is executed, the display re-
turns to its former status.
11: Inlow start
Inputs the inlow start signal
12: Discharge start
Inputs the discharge inlow signal
13: Inlow and discharge ch-
angeover
Switches the weighing mode between inlow and
discharge (ON: Discharge; OFF: Inlow)
14: Clears the last accumula-
ted data
Clears the last accumulated data
15: Accumulation clear
Clears the accumulation value and accumulation times
16: Error cancellation
Cancels the error
17: Print
Inputs the print signal
18: Hold
Inputs the hold signal
19: Emergency stop
Inputs the emergency signal
20: Manual overshoot com-
pensation
Execute overshoot compensation
21: Net weight display
Displays changes to load display net weight