Item
Function No.
Number Return command set value
External control input
INPUT1 operation setting
70
60
0: OFF
1: [ON-OFF] key operation
2: [SET] key operation
3: [ACCUM] key operation
4: [PRESET TARE WEIGHT] key operation
5: [TARE WEIGHT] key operation
6: [NET-GROSS WEIGHT] key operation
7: [ZERO] key operation
8: [F] key operation
9: Zero clear
10: Tare weight clear
11: Inlow start
12: Discharge start
13: Inlow/Discharge changeover
ON: Discharge; OFF: Inlow
14: Clear the last accumulation data
15: Accumulation clear
16: Error cancellation
17: Print command
18: Hold
19: Emergency stop
20: Manual overshoot compensation
21: Net weight display
22: Forced inlow inish
23: Forced discharge inish
24: Accumulation clear for all brands
25: Brand No. 1
26: Brand No. 2
27: Brand No. 4
External control INPUT2 opera-
tion setting
70
61
Optional, in addition to F-60
External control INPUT3 opera-
tion setting
70
62
Optional, in addition to F-60
External control INPUT4 opera-
tion setting
70
63
Optional, in addition to F-60
External control INPUT5 opera-
tion setting
70
64
Optional, in addition to F-60
External control INPUT6 opera-
tion setting
70
65
Optional, in addition to F-60
External control INPUT7 opera-
tion setting
70
66
Optional, in addition to F-60
External control INPUT8 opera-
tion setting
70
67
Optional, in addition to F-60
External control INPUT9 opera-
tion setting
70
68
Optional, in addition to F-60
18 Options
Weight indicator CSD-903
Minebea Intec
EN-197