Can be tare at the same time
depend on the settings.
Judge
Waiting timer for judge
Setpoint
Zero band
Batch start
Setpoint – Preset 2
Setpoint – Preset 1
Setpoint – Overshoot
Final
0
Weighing
Batch start delay timer
Batch monitoring timer
Coarse flow
Middle flow
Fine flow
Time
Gross
Tare
Coarse flow weighing
delay timer
Middle flow weighing
delay timer
Fine flow weighing
delay timer
Stable
+tolerance (over setpoint)
-tolerance (under setpoint)
OK
Batch finish output on
can be changed to
simple comparative
Net
11.4.3
Supplementary batch (discharge) mode
Supplementary batch (discharge) turns on ine inlow automatically for a ixed period of
time when the batch (discharge) weight is insuicient in sequential batch (discharge)
mode.
To apply supplementary batch (discharge), set [Maximum times of supplementary low],
[Time of supplementary batch] and [Waiting time after supplementary batch].
Refer to Chapter
.
Judgment condition
Status display
Judgment condition
Z-BAND
|Gross weight or (Net weight)| ≤ ZERO BAND (SET7).
F. (Coarse) FLOW
Net weight ≥ [Final (SET1) – Prelim 2 (SET4)]
M. (Middle) FLOW
Net weight ≥ [Final (SET1) – Prelim 1 (SET3)]
D. (Fine) FLOW
Net weight ≥ [Final (SET1) – Overshoot (SET2)]
UNDER
Net weight < [Final (SET1) – Under (SET6)]
Weight indicator CSD-903
11 Weighing mode
EN-102