Status
Status is written as bits to input register addresses 51, 55, 59 and 63.
Bit
Details
Bit 15
STABLE
Bit 14
TARE WEIGHT CANCELLATION SETTING
Bit 13
TARE WEIGHT CANCELLATION
Bit 12
GROSS WEIGHT
Bit 11
NET WEIGHT
Bit 10
CENTER OF ZERO
Bit 9
HOLD
Bit 8
ERROR
Bit 7
NEAR ZERO
Bit 6
FULL (Coarse) FLOW/S1
Bit 5
MEDIUM (Middle) FLOW/S2
Bit 4
SMALL (Fine) INFLOW/S3
Bit 3
OVER/S4
Bit 2
OK/S0
Bit 1
UNDER
Bit 0
FULL
-
Status error codes
Status error codes are written as numbers to input register addresses 52, 56, 60 and
64.
Number
Details
1
If zero setting was performed outside the valid zero setting range
2
If an unlisted number was selected for C function or function setting
4
A/D conversion error
8
If tare weight cancellation was performed outside the tare weight can-
cellation operation range
10
Lights when the weight display exceeds [(–weighing value) – 9 D],
exceeds [–110% of weighing value], or exceeds [–20 D] (depending on
C function CF-03 setting).
11
Lights when the weight display exceeds [(+weighing capacity) + 9 D] or
exceeds [+110% of weighing capacity] (depending on C function CF-03
setting).
12
A/D converter input negative overload
13
A/D converter input positive overload
Weight indicator CSD-903
17 ModBus communication
EN-142
Minebea Intec