- 3-3 -
In cace defective printing is not resolved
When the station interior is severely contaminated or defective printing is not resolved after
executing the head cleaning function (
P.2-20), clean the suction nozzle and cap using
the cleaning kit.
The cleaning kit contains the following contents. Do not use alcohol or water.
• Maintenance cleaning liquid
• Gloves,Cleaning swab, goggles
• When cleaning the ink station and head, be sure to wear the supplied
goggle and gloves since you may get ink in your eyes.
• Do not move the carriage out of the capping station by hand. Use the
appropriate operation key to move the carriage.
STEPS:
1.
Press the [FUNCTION] key from the LO-
CAL mode.
2.
Press the [ ] or [ ] keys until the display
gives the indication [MAINTENANCE].
3.
Press the [ENTER] key.
4.
Press the [ ] or [ ] keys until the display
gives the indication [STATION].
5.
Press the [ENTER] key.
6.
Press the [ENTER] key.
Move the carriage.
7.
Open the right maintenance cover.
<< LOCAL >>
STATION
CARRIAGE OUT
: ent
MAINTENANCE
STATION
< ent >
FUNCTION
LIST
< ENT >
FUNCTION
MAINTENANCE
< ENT >
FUNCTION
DATA CLEAR
< ENT >