- 5-18 -
Setting UV lamp off duration
Set the UV lamp OFF duration stored in this unit.
CONT. IRR. [OFF] .........
UV irradiation device turns the lamp off automatically according to setting
value. The initial setting value is 30 minutes.
CONT. IRR [ON] .............
UV lamp is always lighting on. When turning the lamp off action, refer to the “
Turning off UV irradiation device” to set the lamp to OFF. (
P.4-14)
STEPS:
1.
Select the [UV LAMP] from the [MAINTE-
NANCE]. (
P.5-2)
2.
Press the [ENTER] key.
3.
Select [OFF TIMER] by pressing the [ ] or
[ ] keys.
4.
Press the [ENTER] key.
5.
Select “OFF” for [CONT. IRR.] by pressing
the [ ] or [ ] keys.
6.
Press the [ENTER] key.
7.
Enter the Off timer value by the minites by
pressing the [ ] or [ ] keys.
8.
Press the [ENTER] key.
9.
Press the [END] key, and then the device
returns to the LOCAL mode.
MAINTENANCE
UV LAMP
<ent>
<<LOCAL>>
UV LAMP
OFF TIMER
<ent>
OFF TIMER
00h 00m
UV OFF TIMER
CONT. IRR.
: OFF
UV LAMP
OFF TIMER
<ent>
UV LAMP
LEVEL CHECK
<ent>
UV OFF TIMER
CONT. IRR.
: ON
UV OFF TIMER
CONT. IRR.
: OFF
OFF TIMER
01h 30m