- 2-21 -
Printing an image from source data
Starting the printing operation
The following describes the method of printing.
For various function settings necessary for printing, refer to “CHP5 Setting Function”.
• If the temperature in the water heater or in the UV device has not reached
the predetermined value, a message is indicated. In this case, printing is
disabled. It is enabled when the error indication has disappeared.
• Data can be transmitted even when both errors are indicated. Printing
starts after the indication has disappeared.
STEPS:
1.
Make sure to set the media and turn the
vacuum switch has been on.
2.
The device enters the LOCAL mode.
3.
Press the [REMOTE] key.
• Adjust the head gap when Sense
mode has been set. See the descrip-
tion of gap check (
P.2-13).
• In other mode, gap check is per-
formed as well with the latest mode
and the head gap value in the case
the head gap mode is changed or
after turning on the main power.
• When registration mark detection has
been set, the registration marks are
detected in the same procedure as
registration mark checking. For de-
tails, see Chapter 4.
(
P.4-8). When registration mark
detection is not necessary, press the
[END] key. <REMOTE> screen is
restored.
• When setting the [LAYER] by the UV
level, indicate the number of layer at
the right bottom of the remote display
to confirm the intensity of the light
level. Press the jog key [ ] or [ ] in
this mode to change a layer and that
allows the change of the UV level.
< REMOTE >
MARK DETECT
*****.* *****.*
<< LOCAL >>
** TABLE FALL**
PLEASE WAIT
< REMOTE >
UV NOT READY
< REMOTE >
WATER NOT READY
< REMOTE >
1
The number of layer
by the UV level
Содержание UJF-605C
Страница 2: ......
Страница 68: ...2 30...
Страница 88: ...3 20...
Страница 104: ...4 16...
Страница 148: ...A 6...
Страница 153: ......
Страница 154: ...Printed in Japan MIMAKI ENGINEERING CO LTD 2012 IT FW 3 2...