Section 6 - Storage
90-864839061 NOVEMBER 2006
Page 121
MANUAL DRAIN SYSTEM
a
17255
a
a -
Blue drain plug locations
Air Actuated Single Point Drain System
BOAT IN THE WATER
NOTE: This procedure is written for the air pump that is attached to the engine. However,
any air source can be used.
1. Close the seacock (if equipped) or remove and plug the water inlet hose.
2. Remove the air pump from the engine.
3. Ensure that the lever on top of the pump is flush with the handle (horizontal).
4. Install the air pump on the actuator fitting.
5. Pull lever on air pump (vertical) to lock pump on the fitting.
8293
b
d
e
a
c
a -
Actuator fitting
b -
Green indicators
c -
Manual release valve
d -
Air pump
e -
Lever (locking)
Содержание 496 MAG Bravo
Страница 26: ...Section 1 Warranty Notes Page 18 90 864839061 NOVEMBER 2006 ...
Страница 50: ...Section 2 Getting to Know Your Power Package Notes Page 42 90 864839061 NOVEMBER 2006 ...
Страница 72: ...Section 4 Specifications Notes Page 64 90 864839061 NOVEMBER 2006 ...
Страница 74: ...Section 5 Maintenance Page 66 90 864839061 NOVEMBER 2006 ...
Страница 142: ...Section 7 Troubleshooting Notes Page 134 90 864839061 NOVEMBER 2006 ...