Barrier MHTM
TM
MicroDrive
Assembly and installation
68
5815,5001US / Version 02.66
8.7
Assemble light barrier post
The light barrier post is attached with 4 foundation anchors each.
Requirements mounting material
MAGNETIC Automation Corporation recommends using
3/8"
anchor bolts.
Refer to the anchor bolt manufacturers installation
requirements.
Assemble light barrier post
1. The foundation must have cured.
2. Drill holes for the foundation anchors according to the
foundation plan, page 60, Fig. 17. In compliance with the
indicated sizes.
Drill-hole distance: 3.94 in (100 mm), square alignment
Depth: 3.15 in (80 mm)
(At this drilling depth, a minimum tensile strength of
2.02 kpf (9 kN) must be guaranteed.)
3. Set four foundation anchors.
4. Set up post upright on foundation.
5. Attach the post to the foundation with the anchor bolts and
tighten the nuts securely.