Barrier MHTM
TM
MicroDrive
Electrical connection
96
5815,5001US / Version 02.66
NOTE!
If four induction loops must be supervised, you can
connect another plug-in module with the "Detector"
function into the control unit. This plug-in module
registers as "Detector 2 (C-D)". To prevent mutual
interference between the induction loops, we re-
commend using a plug-in module instead of an
external detector.
9.4.4
Connect and test the safety light barriers
Connecting safety light
barrier
Connect the transmitter and receiver connection lines of the safety
light barriers to clamps X11 and X20.
By default, MAGNETIC installs a jumper between terminals X11
OUT and IN. When a safety light barrier is connected, the jumper
must be removed.
See page 181, chapter 18.1 "Wiring diagrams".
Aligning the safety light barrier
The receiver is mounted at the post and the transmitter at the
barrier housing.
1. There must not be any objects between the transmitter and
receiver. The light path must be free.
2. Switch on power supply.
3. The green LEDs at the transmitter and receiver must be lit.
4. Align receiver with transmitter. The yellow LED at the receiver
lights up when aligned correctly.
5. Slightly loosen the attachment screws from the post to align
the receiver. It must be possible to turn the post.
6. Turn the post, until the yellow LED at the receiver is lit.
Check safety light barrier function
Perform function test by holding an object into the light path
between the transmitter and receiver.
The following items must be met:
The yellow LED at the receiver must go out.
The barrier cannot be closed.
9.4.5
Connecting emergency opening contacts
Fire-fighter switch, emergency opening contacts, etc. are
connected to the "Open high priority" input. When the signal is
applied to this input, the barrier opens. While the signal is present,
the barrier cannot be closed.
See page 91, chapter 9.4.6 "Digital inputs" and page 181,
chapter 18.1 "Wiring diagrams".
Содержание MHTM MicroDrive
Страница 1: ...Operating Instructions Barrier MHTMTM MicroDrive Doc ID 5815 5001US Version 02 6...
Страница 4: ...Barrier MHTM TM MicroDrive 4 5815 5001US Version 02 66...
Страница 10: ...Barrier MHTM TM MicroDrive 10 5815 5001US Version 02 66...
Страница 178: ...Barrier MHTM TM MicroDrive 178 5815 5001US Version 02 66...
Страница 179: ......
Страница 180: ...Barrier MHTM TM MicroDrive 180 5815 5001US Version 02 66...
Страница 182: ...Barrier MHTM TM MicroDrive Appendix 182 5815 5001US Version 02 66...
Страница 184: ......
Страница 186: ......
Страница 188: ......
Страница 195: ...Barrier MHTM TM MicroDrive 5815 5001US Version 02 6 195...