Barrier MHTM
TM
MicroDrive
Parameterising control unit
5815,5001US / Version 02.66
113
10.7.1
Mode 1: Maintained contact
Typical application
This mode is suitable for barriers that are integrated in a superordi-
nated system like a plant, e.g. to control access to machines. In
this mode, the barrier must be operated by an operator.
Function
The barrier is controlled only by one switch.
When the switch is closed, the barrier closes. When the switch is
opened, the barrier opens.
Supported input functions
Input function
Signal type
Supported/
Not supported
Open low priority
–
Not supported
Open low priority with
vend count
– Not
supported
Open high priority
(priority 1)
Pulse signal
Supported
Opening loop
–
Not supported
Close
(priority 2)
Permanent signal Supported
Table 35: Supported input functions "Maintained contact"
See page 97, chapter 9.4.6 "Digital inputs".