Barrier MHTM
TM
MicroDrive
Parameterising control unit
5815,5001US / Version 02.66
139
Operating view
Main menu
Attachments
Signal light
Parameters
Description
Lead time
In some application cases, it is required for reasons of safety that a warning
signal for the following traffic lights up after before closing of the barrier. This
warning signal must light up before the barrier closes. The warning signal is
switched on with the closing signal and the lead time is started. The barrier
closes only after the end of the set lead time With this parameter, you can also
set the "Close delay" in the "Delays" menu.
Setting range
0 to 15 s
Factory setting
0 s
Start event
Select the start event from when on the signal lights should be switch.
Options
Closing signal
Safety loop active
The option "Safety loop active" is only sensible for the automatic program
modes 5 to 8. If an opening signal is pending, the signal lamps are not
switched.
Factory setting
Closing signal
Table 51: Menu "Signal light"
Содержание MHTM MicroDrive
Страница 1: ...Operating Instructions Barrier MHTMTM MicroDrive Doc ID 5815 5001US Version 02 6...
Страница 4: ...Barrier MHTM TM MicroDrive 4 5815 5001US Version 02 66...
Страница 10: ...Barrier MHTM TM MicroDrive 10 5815 5001US Version 02 66...
Страница 178: ...Barrier MHTM TM MicroDrive 178 5815 5001US Version 02 66...
Страница 179: ......
Страница 180: ...Barrier MHTM TM MicroDrive 180 5815 5001US Version 02 66...
Страница 182: ...Barrier MHTM TM MicroDrive Appendix 182 5815 5001US Version 02 66...
Страница 184: ......
Страница 186: ......
Страница 188: ......
Страница 195: ...Barrier MHTM TM MicroDrive 5815 5001US Version 02 6 195...