Barrier MHTM
TM
MicroDrive
Assembly and installation
58
5815,5001US / Version 02.66
Laying the foundation,
Installing empty conduits
A
A
1
2
3
4
5
Mag00155
6
7
(135)
5.31
(135)
5.31
(160)
6.30
7.09
6.30
(160)
23.6
(600)
17.7
(450)
19.7
(500)
(180)
(180)
7.09
min.
31.5
(800)
Fig. 15: Foundation plan
Dimensions in inch or feet are without parenthesis. Dimensions in
mm are in parenthesis.
1
Foundation anchor (4 pcs.)
2
Optional when using loop connection;
empty conduit for loop connection, diameter: 1.14 in (29 mm)
3
Empty conduit for induction loop, diameter: 1.14 in (29 mm)
4
Empty conduit for control lines, diameter: 1.14 (29 mm)
5
Concrete foundations (C35/45 XD3 XF2)
6 Roadway
7
Foundation depth: at least 31.5 in (800 mm), frost-protected
foundation depth to be adjusted to the local situation.
1. Dig foundation hole pursuant to Fig. 14 and Fig. 15.
Mag00156
6.50
(165)
6.50
(165)
(3 x
12
Æ
(5 x
8
Æ
450 x 390)
640 x 410)
5 x
0.31
Æ
17.7 x 16.6
3 x
0.47
Æ
25.2 x 16.1
Fig. 16: Reinforcement grid
Dimensions in inch or feet are without parenthesis. Dimensions in
mm are in parenthesis.
2. Place reinforcement grid pursuant to Fig. 16 in the foundation
hole.
Содержание MHTM MicroDrive
Страница 1: ...Operating Instructions Barrier MHTMTM MicroDrive Doc ID 5815 5001US Version 02 6...
Страница 4: ...Barrier MHTM TM MicroDrive 4 5815 5001US Version 02 66...
Страница 10: ...Barrier MHTM TM MicroDrive 10 5815 5001US Version 02 66...
Страница 178: ...Barrier MHTM TM MicroDrive 178 5815 5001US Version 02 66...
Страница 179: ......
Страница 180: ...Barrier MHTM TM MicroDrive 180 5815 5001US Version 02 66...
Страница 182: ...Barrier MHTM TM MicroDrive Appendix 182 5815 5001US Version 02 66...
Страница 184: ......
Страница 186: ......
Страница 188: ......
Страница 195: ...Barrier MHTM TM MicroDrive 5815 5001US Version 02 6 195...