Barrier MHTM
TM
MicroDrive
Electrical connection
5815,5001US / Version 02.66
93
Connecting mains supply
Mag00207
1
2
3
4
Fig. 40: Connecting the mains supply
1
Terminal clamps for mains supply
2 Phase
L
3
Neutral conductor N
4
Ground conductor PE
9.4
Connect customer's control lines (signalling devices)
The following connections are available for control and feedback
on customer’s side:
8 Digital inputs for controlling the barrier.
4 Digital outputs to feed back information.
6 Relays outputs to feed back information. 3 Relays are
normally-open contacts (NO) and 3 relays are change-over
contacts.
DANGER!
Mortal danger by electric voltage!
1. Disconnect barrier system supply voltage. Ensure that there is
no voltage applied. Secure against reactivation.
Connecting the control lines
2. Guide control lines into the connection space through the
cable openings.
Place control lines properly in the barrier housing. The
control lines must not get into moving components.
Attach control lines clamps and cable ties. The clamps can
be removed from the rail by slight compression and
relocated in the desired position. The cable ties can be
attached to the metal tabs.
3. Connect control lines according to wiring diagram. Control
lines must be wired so that no damage could occur due to
moving parts.
See page 181, chapter 18.1 "Wiring diagrams".
Содержание MHTM MicroDrive
Страница 1: ...Operating Instructions Barrier MHTMTM MicroDrive Doc ID 5815 5001US Version 02 6...
Страница 4: ...Barrier MHTM TM MicroDrive 4 5815 5001US Version 02 66...
Страница 10: ...Barrier MHTM TM MicroDrive 10 5815 5001US Version 02 66...
Страница 178: ...Barrier MHTM TM MicroDrive 178 5815 5001US Version 02 66...
Страница 179: ......
Страница 180: ...Barrier MHTM TM MicroDrive 180 5815 5001US Version 02 66...
Страница 182: ...Barrier MHTM TM MicroDrive Appendix 182 5815 5001US Version 02 66...
Страница 184: ......
Страница 186: ......
Страница 188: ......
Страница 195: ...Barrier MHTM TM MicroDrive 5815 5001US Version 02 6 195...