Barrier MHTM
TM
MicroDrive
Parameterising control unit
132
5815,5001US / Version 02.66
Operating view
Main menu
Settings
Start-up behaviour (Start-up behav.)
Option
Description
2
Reference run
In this option, the barrier initially performs a reference run. This means that the
barrier opens completely at low speed.
Release signal
A release signal must be applied for the barrier to be ready fro closing. The
release signal can be applied even before the voltage returns.
The release signal can be given by an external closing signal or by pushing the
left operating button at the control unit.
Closing behaviour
Program modes 1 or 2:
If a safety loop is installed, the barrier closes only after a vehicle has
passed through and a permanent closing signal is pending. If only a safety
light barrier is installed, no passage is required. The barrier closes at once
when a permanent closing signal is applied.
Program modes 3 to 8:
If a safety loop is installed, the barrier closes when the first vehicle has
driven through. If only a safety light barrier is installed, the barrier closes at
once when the voltage returns.
3
Reference run
In this option, the barrier initially performs a reference run. This means that the
barrier opens completely at low speed.
Release signal
A release signal must be applied for the barrier to be ready fro closing.
If the release signal is applied before return of voltage, the release signal is
ineffective. In this case, the release signal must be revoked and applied again
after the barrier opens.
The release signal can be given by an external closing signal or by pushing the
left operating button at the control unit.
Closing behaviour
Program modes 1 or 2:
If a safety loop is installed, the barrier closes only after a vehicle has
passed through and a permanent closing signal is pending. If only a safety
light barrier is installed, no passage is required. The barrier closes at once
when a permanent closing signal is applied.
Program modes 3 to 8:
If a safety loop is installed, the barrier closes only after the first vehicle has
driven through. If only a safety light barrier is installed, the barrier closes at
once when the voltage returns.
Содержание MHTM MicroDrive
Страница 1: ...Operating Instructions Barrier MHTMTM MicroDrive Doc ID 5815 5001US Version 02 6...
Страница 4: ...Barrier MHTM TM MicroDrive 4 5815 5001US Version 02 66...
Страница 10: ...Barrier MHTM TM MicroDrive 10 5815 5001US Version 02 66...
Страница 178: ...Barrier MHTM TM MicroDrive 178 5815 5001US Version 02 66...
Страница 179: ......
Страница 180: ...Barrier MHTM TM MicroDrive 180 5815 5001US Version 02 66...
Страница 182: ...Barrier MHTM TM MicroDrive Appendix 182 5815 5001US Version 02 66...
Страница 184: ......
Страница 186: ......
Страница 188: ......
Страница 195: ...Barrier MHTM TM MicroDrive 5815 5001US Version 02 6 195...