Barrier MHTM
TM
MicroDrive
Parameterising control unit
5815,5001US / Version 02.66
137
10.11 Menu "Attachments"
10.11.1 Signal light
The parameters "Signal mode A", "Signal mode B" and "Signal
mode C" can be used to parameterise the function for the outputs
"Signal light A", "Signal light B" and "Signal light C".
See
page 99, Table 28
You can connect three signal lights.
If you want to control light strips via the MAGNETIC control unit,
you need to select the "Illumination strip red" option for "Signal
Mode A" and "Illumination strip green" for "Signal Mode B".
Operating view
Main menu
Attachments
Signal light
Parameters
Description
Signal mode A
(continued on next
page)
Select function for output "Signal light A".
The parameter "lead time" can be used to parameterise the warning lamp so
that it already lights up red or flashes before closing. The lead time is the time
between the closing signal and commencement of the closing procedure.
Options
Traffic light (permanent signal for red/green signal lights):
Barrier closed: Traffic light red
Barrier opens: Traffic light red
Barrier open (upper end position): Traffic light off
Barrier closes (without lead time)/
closing time (with lead time): Traffic light red
Warning signal (connection of a visual or acoustic signal/
permanent signal before and during closing of the barrier):
Barrier closed: Warning signal off
Barrier opens: Warning signal off
Barrier open (upper end position): Warning signal off
Barrier closes (without lead time)/
closing time (with lead time): Warning signal red
Flashing light (flashing light connection/
flashing signal while the barrier opens or closes):
Barrier closed: Flashing light off
Barrier opens: Flashing light flashes at 2 Hz
Barrier open (upper end position): Flashing light off
Barrier closes (without lead time)/
closing time (with lead time): Flashing light flashes at 2 Hz
Boom illumination (boom illumination connection/
permanent flashing signal except when the barrier is open):
Barrier closed: Illumination flashes at 2 Hz
Barrier opens: Illumination flashes at 2 Hz
Barrier open (upper end position): Illumination off
Barrier closes (without lead time)/
closing time (with lead time): Illumination flashes at 2 Hz
Содержание MHTM MicroDrive
Страница 1: ...Operating Instructions Barrier MHTMTM MicroDrive Doc ID 5815 5001US Version 02 6...
Страница 4: ...Barrier MHTM TM MicroDrive 4 5815 5001US Version 02 66...
Страница 10: ...Barrier MHTM TM MicroDrive 10 5815 5001US Version 02 66...
Страница 178: ...Barrier MHTM TM MicroDrive 178 5815 5001US Version 02 66...
Страница 179: ......
Страница 180: ...Barrier MHTM TM MicroDrive 180 5815 5001US Version 02 66...
Страница 182: ...Barrier MHTM TM MicroDrive Appendix 182 5815 5001US Version 02 66...
Страница 184: ......
Страница 186: ......
Страница 188: ......
Страница 195: ...Barrier MHTM TM MicroDrive 5815 5001US Version 02 6 195...