Electrical connection
100
5815,5001US / Version 02.66
Function
Description
Error
When the control unit recognizes any "safety-relevant error" or "error", the
output with this function is reactivated (Fail safe).
Warning
When the control unit recognizes any "Warning", the output with this
function is reactivated (Fail safe).
Closed
When the barrier is closed, the output with this function is active.
Open
When the barrier is open, the output with this function is active.
Closing
While the barrier closes, the output with this function is active.
Opening
While the barrier opens, the output with this function is active.
Boom angle
This function is used to set the upper and lower angles. When the barrier
arm is within this angle range, the output with this function is active. When
the barrier arm is outside of the angle range set, the output is inactive. The
upper and lower angle can be set for values between 0° and 90°.
Pulse after passage
When a passage was detected, this output emits a counter pulse of 300 ms
with this function. Passage is possible in either direction.
Sliding door pulse
This output is used to control a sliding gate. When the barrier is open, the
output with this function emits a counter pulse of 300 ms with this function.
Boom contact FB
(Boom contact feedback)
The barrier can optionally be equipped with a boom contact in the flange.
When the boom contact triggers, the output with this function is deactivated
(fail safe). The output is activated again once the boom contact is re-
established and the boom is opened again entirely..
Boom locking
The barrier can optionally be equipped with a boom lock. This output serves
control of the electro-mechanical boom lock at the end of the barrier arm.
When the barrier is closed, the boom lock is activated via this output. If a
signal is present for opening, the boom lock is removed first. The barrier
opens with a short delay. The parameter “With boom locking” must be
activated in the menu “Boom locking”.
→
See page 141, chapter 10.11.3.
Parallel operation
This output can be used to operate two barriers synchronously. This output
function must be activated via the menu "Master/Slave".
See page 136,
chapter 10.10.11.
For information on parallel operation, see separate instructions.
Acknowledgment
This output is required for parallel operation.
For information on parallel operation, see separate instructions.
Signal light A
This output is used to control a signal light. The function of this output can
be parameterised via the parameter "Signal light A", page 137, chapter
10.11.1.
Signal light B
This output is used to control a signal light. The function of this output can
be parameterised via the parameter "Signal light B", page 137, chapter
10.11.1.
Signal light C
This output is used to control a signal light. The function of this output can
be parameterised via the parameter "Signal light C", page 137, chapter
10.11.1.
Loop active A
When the induction loop A is busy, the output with this function is active.
Loop active B
When the induction loop B is busy, the output with this function is active.
Loop active pulse A
When a vehicle drives into loop A (rising flank), the output with this function
emits a pulse.
Содержание MHTM MicroDrive
Страница 1: ...Operating Instructions Barrier MHTMTM MicroDrive Doc ID 5815 5001US Version 02 6...
Страница 4: ...Barrier MHTM TM MicroDrive 4 5815 5001US Version 02 66...
Страница 10: ...Barrier MHTM TM MicroDrive 10 5815 5001US Version 02 66...
Страница 178: ...Barrier MHTM TM MicroDrive 178 5815 5001US Version 02 66...
Страница 179: ......
Страница 180: ...Barrier MHTM TM MicroDrive 180 5815 5001US Version 02 66...
Страница 182: ...Barrier MHTM TM MicroDrive Appendix 182 5815 5001US Version 02 66...
Страница 184: ......
Страница 186: ......
Страница 188: ......
Страница 195: ...Barrier MHTM TM MicroDrive 5815 5001US Version 02 6 195...