Barrier MHTM
TM
MicroDrive
Parameterising control unit
5815,5001US / Version 02.66
117
10.7.5
Automatic modes 5 to 8: Drive direction 1 –
overview and differences
The automatic modes differ in their functions in drive direction 1
"Safety loop
Opening loop".
In drive direction 2 "Opening loop
Safety loop", the automatic
modes are identical.
Drive direction 1: "Safety loop
Opening loop"
Mag00096
1
2
3
4
5
Fig. 46: Program modes 5 to 8, Passage in direction 1
1
Remote control, card reader, coin accepter, etc.
2 Barrier
3 Opening
loop
4 Safety
loop
5
Passage in direction 1
Program mode
Hold-open time
Function
Opening loop
Closing time
drive backwards
Closing time
without drive
through
Automatic (5)
The opening loop
here acts as an
extended safety
loop.
Automatic (6)
With hold-open
time
The opening loop
does not act as an
extended safety
loop here.
Barrier closes after
the end of the
opening time or at
a closing signal.
Automatic (7)
The opening loop
here acts as an
extended safety
loop.
Automatic (8)
Without hold-open
time
The opening loop
does not act as an
extended safety
loop here.
If a vehicle drives
onto the safety
loop and leaves it
again backwards,
the barrier closes.
Barrier closes after
drive-through of
the next vehicle or
after the closing
signal.
Table 39: Differences of automatic program modes 5 to 8, direction 1
Содержание MHTM MicroDrive
Страница 1: ...Operating Instructions Barrier MHTMTM MicroDrive Doc ID 5815 5001US Version 02 6...
Страница 4: ...Barrier MHTM TM MicroDrive 4 5815 5001US Version 02 66...
Страница 10: ...Barrier MHTM TM MicroDrive 10 5815 5001US Version 02 66...
Страница 178: ...Barrier MHTM TM MicroDrive 178 5815 5001US Version 02 66...
Страница 179: ......
Страница 180: ...Barrier MHTM TM MicroDrive 180 5815 5001US Version 02 66...
Страница 182: ...Barrier MHTM TM MicroDrive Appendix 182 5815 5001US Version 02 66...
Страница 184: ......
Страница 186: ......
Страница 188: ......
Страница 195: ...Barrier MHTM TM MicroDrive 5815 5001US Version 02 6 195...