Barrier MHTM
TM
MicroDrive
Parameterising control unit
134
5815,5001US / Version 02.66
Operating view
Main menu
Settings
Start-up behaviour (Start-up behav.)
Option
Description
6
Reference run
In this option, the barrier arm stops initially.
Release signal
The barrier carries out a reference run after the left operating button on the
control unit is pressed.
Closing behaviour
Program modes 1 or 2:
The barrier closes at once when a permanent closing signal is applied.
Program modes 3 to 8:
The barrier closes at once after the barrier reference run.
7
Reference run
In this option, the barrier initially performs a reference run. This means that the
barrier opens at low speed.
Release signal
No release signal is required to close the boom.
Closing behaviour
Program modes 1 or 2:
The barrier closes at once when a permanent closing signal is applied.
Program modes 3 to 8:
If a safety loop is installed, the barrier closes only after the first vehicle has
driven through or after closing. If only a safety light barrier is installed, the
barrier closes at once when the voltage returns.
WARNING!
Danger of injury from closing arm!
Visual contact to the barrier is required when the closing
signal is given.
No vehicles must stand below the barrier when the
closing signal is given.
Table 47: Menu "Start-up behaviour"
Содержание MHTM MicroDrive
Страница 1: ...Operating Instructions Barrier MHTMTM MicroDrive Doc ID 5815 5001US Version 02 6...
Страница 4: ...Barrier MHTM TM MicroDrive 4 5815 5001US Version 02 66...
Страница 10: ...Barrier MHTM TM MicroDrive 10 5815 5001US Version 02 66...
Страница 178: ...Barrier MHTM TM MicroDrive 178 5815 5001US Version 02 66...
Страница 179: ......
Страница 180: ...Barrier MHTM TM MicroDrive 180 5815 5001US Version 02 66...
Страница 182: ...Barrier MHTM TM MicroDrive Appendix 182 5815 5001US Version 02 66...
Страница 184: ......
Страница 186: ......
Страница 188: ......
Страница 195: ...Barrier MHTM TM MicroDrive 5815 5001US Version 02 6 195...