Barrier MHTM
TM
MicroDrive
Parameterising control unit
5815,5001US / Version 02.66
129
Drive direction 2: "Opening loop
Safety loop"
Mag00097
1
2
3
4
5
Fig. 50: Program mode 5 with pulse storage,
Passage in direction 2
1
Remote control, card reader, coin accepter, etc.
2 Barrier
3 Opening
loop
4 Safety
loop
5
Passage in direction 2
In direction 2, the opening loop is driven on first. The barrier opens.
While the opening loop or safety loop is occupied, the barrier
remains open. When the vehicle has left both loops will the barrier
close.
From drive direction 2, vend Count is not active.
When the vehicle leaves the opening loop backwards, the barrier
closes at one.