Barrier MHTM
TM
MicroDrive
Parameterising control unit
112
5815,5001US / Version 02.66
10.7 Select program mode
8 program modes and the service mode are available for the
MHTM
TM
MicroDrive barriers.
Program modes 1 to 4 are manual modes. In the manual modes,
the barrier must be closed manually after a drive through.
Program modes 5 to 8 are automatic modes. In the automatic
modes, the barrier closes again automatically after a vehicle drives
through.
Program
Description
1 Maintained
contact
2 Deadman
3
Pulse control (bistable)
4
Two-Pulse control (Open/Closed button)
(Factory setting)
5 Automatic
(5):
with hold-open time
6 Automatic
(6):
with hold-open time and decoupling of the
opening loop at drive through in the opposite
direction
7
Automatic (7):
without hold-open time
8
Automatic (8)
without hold-open time and decoupling of the
opening loop at drive through in the opposite
direction
Service
Table 34: Program modes
Another program mode can be selected pursuant to chapter 10.5,
page 110.
NOTE!
For reasons of safety, the first barrier arm motion
after program mode change is performed at slow
speed.
Содержание MHTM MicroDrive
Страница 1: ...Operating Instructions Barrier MHTMTM MicroDrive Doc ID 5815 5001US Version 02 6...
Страница 4: ...Barrier MHTM TM MicroDrive 4 5815 5001US Version 02 66...
Страница 10: ...Barrier MHTM TM MicroDrive 10 5815 5001US Version 02 66...
Страница 178: ...Barrier MHTM TM MicroDrive 178 5815 5001US Version 02 66...
Страница 179: ......
Страница 180: ...Barrier MHTM TM MicroDrive 180 5815 5001US Version 02 66...
Страница 182: ...Barrier MHTM TM MicroDrive Appendix 182 5815 5001US Version 02 66...
Страница 184: ......
Страница 186: ......
Страница 188: ......
Страница 195: ...Barrier MHTM TM MicroDrive 5815 5001US Version 02 6 195...